Search
Now showing items 11-15 of 15
ASSE 1014: Performance Requirements for Backflow Prevention Devices for Hand-Held Showers
Abstract: Description
These devices provide backflow protection against backsiphonage and backpressure in handheld showers. These are separate devices or are integral with wall-mounted or deck-mounted tub fillers, ...
These devices provide backflow protection against backsiphonage and backpressure in handheld showers. These are separate devices or are integral with wall-mounted or deck-mounted tub fillers, ...
ASSE 1017: Performance Requirements for Temperature Actuated Mixing Valves for Hot Water Distribution Systems
Abstract: Description
Temperature Actuated Mixing Valves for Hot Water Distribution Systems (herein referred to as "device") shall consist of a hot water inlet connection, a cold water inlet connection, a mixed ...
Temperature Actuated Mixing Valves for Hot Water Distribution Systems (herein referred to as "device") shall consist of a hot water inlet connection, a cold water inlet connection, a mixed ...
ASSE 1003: Performance Requirements for Water Pressure Reducing Valves for Domestic Water Distribution Systems
Abstract: Description
Devices covered by this standard are self-contained, direct acting, single diaphragm types. Devices shall be permitted to have an integral strainer, separate strainer connected to the valve ...
Devices covered by this standard are self-contained, direct acting, single diaphragm types. Devices shall be permitted to have an integral strainer, separate strainer connected to the valve ...
ASSE 1037: Performance Requirements for Pressurized Flushing Devices (Flushometers) for Plumbing Fixtures
Abstract: This standard establishes physical requirements, basic performance requirements, and test procedures for pressurized flushing devices for the safe, sanitary operation of plumbing fixtures.
While this standard covers ...
While this standard covers ...
ASSE 1001: Performance Requirements for Atmospheric Type Vacuum Breakers
Abstract: Description
Vacuum Breakers shall be classified in two general types:
a. Atmospheric type, as described herein.
b. Pressure type (See ASSE Standard #1020, Performance Requirements for Pressure ...
Vacuum Breakers shall be classified in two general types:
a. Atmospheric type, as described herein.
b. Pressure type (See ASSE Standard #1020, Performance Requirements for Pressure ...