This specification establishes the formulation and manufacturing requirements for a free water detector pad. This uranine coated paper disc is used with the Model Number MK II Free Water Detector, MIL-D-81227; the Type III, Detector, Contaminated Fuel, MIL-D-22612; and the ASTM-D3240 Test Pad Rater.
Intended Use:
The detector pads covered by this specification are intended for use with the Model No. MK II Free Water Detector, MIL-D-81227; the Detector, Contaminated Fuel, Type III, MIL-D-22612; and, the ASTM-D3240 Test Pad Rater (Aqua-Glo) (25 mm pads only). When aviation turbine fuel is filtered through the free water detector pad, the free water in the fuel reacts with the uranine dye on the pad. If free water is present in the fuel, the detector pad will fluoresce under ultra violet light, indicating the quantity of water contaminant in aircraft fuel.
Subject: Contamination
-
Statistics
MIL-DTL-81248C VALID NOTICE 1
Show full item record
contributor author | NAVY - AS - Naval Air Systems Command | |
date accessioned | 2017-09-04T18:49:48Z | |
date available | 2017-09-04T18:49:48Z | |
date copyright | 01/20/2011 | |
date issued | 2011 | |
identifier other | KSXFPDAAAAAAAAAA.pdf | |
identifier uri | http://yse.yabesh.ir/std;jsessionid=3826AF679D40527318548F1EFDEC014A/handle/yse/231177 | |
description abstract | Scope: This specification establishes the formulation and manufacturing requirements for a free water detector pad. This uranine coated paper disc is used with the Model Number MK II Free Water Detector, MIL-D-81227; the Type III, Detector, Contaminated Fuel, MIL-D-22612; and the ASTM-D3240 Test Pad Rater. The detector pads covered by this specification are intended for use with the Model No. MK II Free Water Detector, MIL-D-81227; the Detector, Contaminated Fuel, Type III, MIL-D-22612; and, the ASTM-D3240 Test Pad Rater (Aqua-Glo) (25 mm pads only). When aviation turbine fuel is filtered through the free water detector pad, the free water in the fuel reacts with the uranine dye on the pad. If free water is present in the fuel, the detector pad will fluoresce under ultra violet light, indicating the quantity of water contaminant in aircraft fuel. | |
language | English | |
title | MIL-DTL-81248C VALID NOTICE 1 | num |
title | Detector Pad, Free Wate | en |
type | standard | |
page | 1 | |
status | Active | |
tree | NAVY - AS - Naval Air Systems Command:;2011 | |
contenttype | fulltext | |
subject keywords | Contamination | |
subject keywords | Denatured alcohol | |
subject keywords | Jet fuel | |
subject keywords | Sodium fluorescein | |
subject keywords | Undissolved water |