Abstract: Description of Driving Event:
The QD/filter assemblies are designed to provide a disconnect interface and remove all solid particles (exceeding 25 microns) from the servicing fluids at various system operating pressures, contaminant capacities, and rated flows. Servicing fluids include O2, H2, freon, coolant water, and potable water. Assemblies consist of a quick disconnect, filter, and associated caps, fittings, seals, and tethered nameplate/identification tags. The QD has internal bellows which permit movement of a probe assembly that opens flight-half coupling. A pod component failure may cause contamination in the orbiter onboard reactants.
The QD/filter assemblies are designed to provide a disconnect interface and remove all solid particles (exceeding 25 microns) from the servicing fluids at various system operating pressures, contaminant capacities, and rated flows. Servicing fluids include O2, H2, freon, coolant water, and potable water. Assemblies consist of a quick disconnect, filter, and associated caps, fittings, seals, and tethered nameplate/identification tags. The QD has internal bellows which permit movement of a probe assembly that opens flight-half coupling. A pod component failure may cause contamination in the orbiter onboard reactants.
Subject: Hardware
Show full item record
contributor author | NASA - National Aeronautics and Space Administration (NASA) | |
date accessioned | 2017-09-04T18:49:49Z | |
date available | 2017-09-04T18:49:49Z | |
date copyright | 33885 | |
date issued | 1992 | |
identifier other | KSYCQCAAAAAAAAAA.pdf | |
identifier uri | http://yse.yabesh.ir/std/handle/yse/231189 | |
description abstract | Description of Driving Event: The QD/filter assemblies are designed to provide a disconnect interface and remove all solid particles (exceeding 25 microns) from the servicing fluids at various system operating pressures, contaminant capacities, and rated flows. Servicing fluids include O2, H2, freon, coolant water, and potable water. Assemblies consist of a quick disconnect, filter, and associated caps, fittings, seals, and tethered nameplate/identification tags. The QD has internal bellows which permit movement of a probe assembly that opens flight-half coupling. A pod component failure may cause contamination in the orbiter onboard reactants. | |
language | English | |
title | NASA-LLIS-0150 | num |
title | Lessons Learned - Quick Disconnect (QD)/Filter Assembly Set (POD) Operations | en |
type | standard | |
page | 2 | |
status | Active | |
tree | NASA - National Aeronautics and Space Administration (NASA):;1992 | |
contenttype | fulltext | |
subject keywords | Hardware |