Browsing AIR FORCE - 99 - Air Force Materiel Command HQ by Issue Date
Now showing items 1-20 of 56
-
FIPS-PUB-138
Abstract: This standard specifies the electrical characteristics of balanced voltage digital interface circuits normally implemented in integrated circuit technology that are to be employed for the interchange of serial binary data, ... -
FIPS-PUB-55
Abstract: GENERAL ZNFORMATION
The following information is supplied as a replacement for the equivalent information originally published in FIPS PUB 55. Some of the descriptive information contained in that ... -
FIPS-PUB-113
Subject(s) : authentication; , cryptography; , data authentication algorithm; , Data Encryption Standard (DES); , data integrity; , Federal Information Processing Standard (FIPS). , -
MIL-HDBK-419A VOL 1
Abstract: PREFACE
This volume is one of a two-volume series which sets forth the grounding, bonding, and shielding theory for communications electronics (C-E) equipments and facilities. Grounding, bonding, and shielding ...Subject(s) : Air Terminal (Lightning Rod) , Bonding , Cathodic Protection , Corrosion , Down Conductor , Earth Electrode Subsystem , Electromagnetic Pulse (EMP) , Equipment Shielding , Equipotential Ground Plane , Facility Ground System , Facility Shielding , Fall-of-Potential Ground Test , Fault Protection Subsystem , Grounded Conductor , Grounding , Grounding Conductor (Green Wire) , Higher Frequency Ground , Lightning , Lightning Protection Subsystem , Lower Frequency Ground , Multipoint Grounding , Neutral Conductor , Phase Conductor , Power System Grounding , Ring Ground , Shielding , Shielding Effectiveness , Signal Grounding , Signal Reference Subsystem , Single-Point Grounding , Zone (Cone) of Protection , -
FIPS-PUB-5-2
Subject(s) : ADP standards; , computers; , data elements and codes; , data processing; , Federal Information Processing Standard; , geography; , information systems; , outlying areas. , standards; , states; , statistical data; , -
MIL-HDBK-419A VOL 2
Abstract: INTROUUCTION.
This chapter presents the design, installation practices, test and acceptance procedures associated with the incorporation of effective grounding, bonding, and shielding for a new facility.* The ...Subject(s) : Air Terminal (Lightning Rod) , Bonding , Cathodic Protection , Corrosion , Down Conductor , Earth Electrode Subsystem , Electromagnetic Pulse (EMP) , Equipment Shielding , Equipotential Ground Plane , Facility Ground System , Facility Shielding , Fault Protection Subsystem , Grounded Conductor , Grounding , Grounding Conductor (Green Wire) , Higher Frequency Ground , Lightning , Lightning Protection Subsystem , Lower Frequency Ground , Multipoint Grounding , Neutral Conductor , Pall-of-Potential Ground Test , Phase Conductor , Power System Grounding , Ring Ground , Shielding , Shielding Effectiveness , Signal Grounding , Signal Reference Subsystem , Single-Point Grounding , Zone (Cone) of Protection ,