English -- Multicore and symmetrical pair/quad cables for digital communications – Part 11: Symmetrical single pair cables with transmission characteristics up to 600 MHz – Horizontal floor wiring – Sectional specification - Edition 1.0

IEC 61156-11

Organization:
IEC - International Electrotechnical Commission
Year: 2019

Abstract: Scope: This part of IEC 61156 describes cables intended to be used for transmission of 1 Gbps over a single twisted pair for office, home and industrial application. An example of existing application is 1000BASE-T1, see ISO/IEC TR 11801-99061. The transmission characteristics of these cables are specified up to a frequency of 600 MHz and at a temperature of 20 °C. The cable type recognised is intended to be used for shielded channels with a nominal length of 40 m. Possible designs are U/FTP, X/UTP and X/FTP, where X stands for F, S or SF. A blank detail specification can be found in Annex A. These cables can comprise more than one pair in the event that several systems are operated in parallel. In this case, refer to Clause 7 of this document. The cables covered by this document are intended to operate with voltages and currents normally encountered in communication systems. While these cables are not intended to be used in conjunction with low impedance sources, for example, the electric power supplies of public utility mains, they are intended to be used to support the delivery of low-voltage remote powering applications. 1 Under consideration.
URI: http://yse.yabesh.ir/std;que/handle/yse/289029
Collections :
  • IEC - International Electrotechnical Commission
  • Download PDF : (1.117Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    English -- Multicore and symmetrical pair/quad cables for digital communications – Part 11: Symmetrical single pair cables with transmission characteristics up to 600 MHz – Horizontal floor wiring – Sectional specification - Edition 1.0

Show full item record

contributor authorIEC - International Electrotechnical Commission
date accessioned2020-09-15T22:28:25Z
date available2020-09-15T22:28:25Z
date copyright2019.05.01
date issued2019
identifier otherUCEWHGAAAAAAAAAA.pdf
identifier otherUCEWHGAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;que/handle/yse/289029
description abstractScope: This part of IEC 61156 describes cables intended to be used for transmission of 1 Gbps over a single twisted pair for office, home and industrial application. An example of existing application is 1000BASE-T1, see ISO/IEC TR 11801-99061. The transmission characteristics of these cables are specified up to a frequency of 600 MHz and at a temperature of 20 °C. The cable type recognised is intended to be used for shielded channels with a nominal length of 40 m. Possible designs are U/FTP, X/UTP and X/FTP, where X stands for F, S or SF. A blank detail specification can be found in Annex A. These cables can comprise more than one pair in the event that several systems are operated in parallel. In this case, refer to Clause 7 of this document. The cables covered by this document are intended to operate with voltages and currents normally encountered in communication systems. While these cables are not intended to be used in conjunction with low impedance sources, for example, the electric power supplies of public utility mains, they are intended to be used to support the delivery of low-voltage remote powering applications. 1 Under consideration.
languageEnglish
titleEnglish -- Multicore and symmetrical pair/quad cables for digital communications – Part 11: Symmetrical single pair cables with transmission characteristics up to 600 MHz – Horizontal floor wiring – Sectional specification - Edition 1.0en
titleIEC 61156-11num
typestandard
page30
statusActive
treeIEC - International Electrotechnical Commission:;2019
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian