UL SUBJECT 504

English -- Outline of Investigation for Mineral-Insulated, Metal-Sheathed Cable - Issue 1

Organization:
UL - UL
Year: 2017

Abstract: Scope: This Outline of Investigation covers mineral-insulated (Type MI) metal-sheathed cable, which consists of one or more solid copper conductors insulated with highly compressed magnesium oxide and enclosed in a continuous copper or alloy steel sheath, with or without a nonmetallic jacket. Cables rated 600 V may be composed of 16 AWG to 500 kcmil single conductor, 16 to 4 AWG two and three conductor, 16 to 6 AWG four conductor, and 16 to 10 AWG seven conductor constructions. Cables rated 300 V may be composed of two, three, four and seven conductor, sizes 18 to 16 AWG, for use on signaling circuits. The copper sheath is suitable as an equipment grounding conductor. For cable with alloy steel outer sheath one of the insulated conductors is to be used for equipment grounding. The cable shall be installed in accordance with Article 332 of National Electrical Code, NFPA 70
URI: http://yse.yabesh.ir/std;jsein=a/handle/yse/232364
Collections :
  • UL - UL
  • Download PDF : (56.74Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    UL SUBJECT 504

Show full item record

contributor authorUL - UL
date accessioned2017-10-18T10:55:16Z
date available2017-10-18T10:55:16Z
date copyright2017.05.05
date issued2017
identifier otherFSUZYFAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsein=a/handle/yse/232364
description abstractScope: This Outline of Investigation covers mineral-insulated (Type MI) metal-sheathed cable, which consists of one or more solid copper conductors insulated with highly compressed magnesium oxide and enclosed in a continuous copper or alloy steel sheath, with or without a nonmetallic jacket. Cables rated 600 V may be composed of 16 AWG to 500 kcmil single conductor, 16 to 4 AWG two and three conductor, 16 to 6 AWG four conductor, and 16 to 10 AWG seven conductor constructions. Cables rated 300 V may be composed of two, three, four and seven conductor, sizes 18 to 16 AWG, for use on signaling circuits. The copper sheath is suitable as an equipment grounding conductor. For cable with alloy steel outer sheath one of the insulated conductors is to be used for equipment grounding. The cable shall be installed in accordance with Article 332 of National Electrical Code, NFPA 70
languageEnglish
titleUL SUBJECT 504num
titleEnglish -- Outline of Investigation for Mineral-Insulated, Metal-Sheathed Cable - Issue 1en
typestandard
page14
statusActive
treeUL - UL:;2017
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian