Lessons Learned - CALIPSO Avalanche Photodiode (APD) Detector Assembly Electrical Failure

contributor authorNASA - National Aeronautics and Space Administration (NASA)
date accessioned2017-09-04T18:09:15Z
date available2017-09-04T18:09:15Z
date copyright07/30/2006
date issued2006
identifier otherGTXCQCAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsery=autho162s7D8308/handle/yse/192241
description abstractAbstract:
The APD detector assembly failed during the Satellite Thermal/Vacuum test due to design-drawing error. The design-drawing error indicated reversed installation of a polarized capacitor. The assembly quality assurance (QA) did not detect the error because the assembly matched the drawing. Make certain that QA is involved at every stage including drawing reviews to aid in systems successfully built, tested, integrated and flown at minimum cost.
languageEnglish
titleNASA-LLIS-1840num
titleLessons Learned - CALIPSO Avalanche Photodiode (APD) Detector Assembly Electrical Failureen
typestandard
page2
statusActive
treeNASA - National Aeronautics and Space Administration (NASA):;2006
contenttypefulltext
subject keywordsSafety and Mission Assurance.
subject keywordsSystems Engineering and Analysis.