Clamp, Loop, Tube 17-7 PH Cres, 500 Degrees F

contributor authorNAVY - AS - Naval Air Systems Command
date accessioned2017-09-04T18:42:52Z
date available2017-09-04T18:42:52Z
date copyright01/13/2010
date issued2010
identifier otherALVQPCAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;query=autho54037D83FCDC527369728F1ED52F014A/handle/yse/224273
description abstractIntended Use: These clamps are intended for use as follows: Temperature range: − 65 to + 500 °F. These clamps have cushions, which have been compounded for high temperature capability at the sacrifice of fluid resistance. It is recommended for use only in those areas with operating temperatures from 275 °F to 500 °F where fluid exposure is minimal. For application below 275 °F, the use of clamps with a higher degree of fluid resistance is recommended such as MIL-DTL-85052/1 or MIL-DTL-85052/2 clamps. Systems: All fluid and electrical systems application in high temperature areas. Vibration rating: Clamps are used at low, medium, and high vibration areas depending on mounting methods. The recommended mounting methods for various vibration areas are specified in 6.4 of the general specification.
languageEnglish
titleMIL-DTL-85052/3C VALID NOTICE 1num
titleClamp, Loop, Tube 17-7 PH Cres, 500 Degrees Fen
typestandard
page1
statusActive
treeNAVY - AS - Naval Air Systems Command:;2010