GASKETS, METALLIC AND RUBBER, FOR USE IN UNION PIPE FITTINGS 1/4 TO 2-INCH NPS WITH VARIOUS FLUIDS FROM -30 DEG. F (-34 DEG. C) TO 400 DEG. F (204 DEG. C)

contributor authorNAVY - SH - Naval Sea Systems Command (Ship Systems)
date accessioned2017-09-04T18:25:57Z
date available2017-09-04T18:25:57Z
date copyright01/12/1994
date issued1994
identifier otherIKEYDAAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsery=autho162sear79D405273/handle/yse/208142
description abstractThis specification covers gaskets, metallic and rubber, consisting of a nitrile or ethylene-propylene rubber inner ring attached to a copper-alloy cast outer metallic ring for use as a static seal in union connections of piping systems in air, water, steam, and petroleum products.
|Gaskets shall be of the following types, categorized by the rubber portion of the gasket (see 3.2.2), as specified (see 6.2).
|    a. Type A - NBR (Nitrile rubber) inner ring     b. Type B - EPM (Ethylene-propylene rubber) inner ring


Gaskets shall conform to the dimensions shown in 3.3.1 for the specified nominal size required (see 6.2).
Intended Use: Gaskets defined in this specification are suitable for use as a static seal in union connections in accordance with MIL-F-1183, MIL-F-24227, or similar applications. The gaskets are compatible with the fluid and corresponding temperature range (minimum/maximum) identified in table IV for each type. Where no limitation is provided for a given classification, that type is not recommended for service with the identified fluid. However, selection of any type for a given application is the responsibility of the user and should consider compatibility of all fluids which are or may be introduced into the system. TABLE IV. Recommended gasket application.|
Classification (see 1.2)          Fluid         --------------------------------------------------------------                                   Type A                          Type B     ---------------------------------------------------------------------------------      Air/gas            −30 °F(−34 °C)/250 °F(121 °C)   −30 °F(−34 °C)/300 °F(149 °C)     Water              −30 °F(−34 °C)/250 °F(121 °C)   −30 °F(−34 °C)/400 °F(204 °C)1     Steam                            -                 400 °F(204 °C) maximum1     Hydraulic fluids   −30 °F(−34 °C)/250 °F(121 °C)                  -  1 Type B gaskets are suitable in steam and water continuous service up to 400 °F(204°C) and intermittent service up to 425 °F(218°C).
TABLE V. Lot acceptance and rejection criteria.1
Reject number2                                         ----------------------------------------     Inspection lot size   Sample size                                           Quality     Rejected lot                                         conformance   resubmittal     Packaging                                         (see 4.4.2)   (see 4.4.3)    (see 4.4.4)     ----------------------------------------------------------------------------             2 to 8              2             1             1              1            9 to 15             3             1             1              1           16 to 25             5             1             1              1            26 to 50             8             1             1              1           51 to 90             13            1             1              2           91 to 150            20            2             1              2           151 to 280            32            2             1              3          281 to 500            50            3             2              4          501 to 1,200          80            4             3              6         1,201 to 3,200         125            6             4              8        3,201 to 10,000        200            8             6             11       10,001 to 35,000        315           11             9             15        35,001 to 150,000       500           15            13             22      150,001 to 500,000       800           22            19             22       500,001 and over       1,250          22            19             22  1 If the inspection lot successfully passes the table III criteria, those units found defective during inspection shall be replaced with acceptable units prior to lot acceptance. For rejected lots, see 4.4.3.  2 Reject number indicates the minimum number of defective units per sample size needed for rejection of the entire inspection lot. Inspect the sample size until the reject number is reached.

languageEnglish
titleMIL-G-24748Anum
titleGASKETS, METALLIC AND RUBBER, FOR USE IN UNION PIPE FITTINGS 1/4 TO 2-INCH NPS WITH VARIOUS FLUIDS FROM -30 DEG. F (-34 DEG. C) TO 400 DEG. F (204 DEG. C)en
typestandard
page18
statusActive
treeNAVY - SH - Naval Sea Systems Command (Ship Systems):;1994
contenttypefulltext
subject keywordsCopper-alloy cast
subject keywordsInner ring
subject keywordsOuter ring
subject keywordsStatic seal