NACE TM0211

Durability Test for Copper/Copper Sulfate Permanent Reference Electrodes for Direct Burial Applications - Item No. 21257

Organization:
NACE - NACE International
Year: 2011

Abstract: This standard describes a test method to measure specific physical properties and the relative stability of Cu/CuSO4 PREs when they are subjected to specific environmental stresses. These reference electrodes, while "permanent" in the physical sense (they are not commonly removed), do exhibit a finite service life. This test method is intended to provide a measure of the relative durability that may be expected. The test method specifically focuses on the ability of the Cu/CuSO4 PRE to (1) resist migration of CuSO4 from within the PRE into its surrounding environment and (2) to resist the migration of chloride from its surrounding environment into the PRE.
Unique field conditions may alter the durability of Cu/CuSO4 PREs. Factors such as temperature, sunlight, and soil contaminants can significantly affect PRE durability. Although consideration of these parameters is outside the scope of this standard, they may require consideration in certain field applications.
Environmental factors must be accounted for while performing durability testing. Articles have been written indicating possible factors resulting in erroneous potential measurements from a half-cell and their relevance to PREs.1.2 Variables that usually affect portable Cu/CuSO4 reference electrodes are temperature and sunlight variations. Both cited articles indicate that potential measurements can vary by 0.9 mV/degrees F), and that exposure to direct sunlight can cause variations in potential up to +20 mV. However, because PREs are typically used in locations with no direct sunlight exposure and limited temperature variations, such effects should be minimal1. Another environmental factor that can cause a change in potential is chloride contamination. This is generally only a problem with prolonged exposure to chloride- rich environments (e.g., seawater, brackish water, or chloride-rich soil). As the chloride contamination increases, the potential shifts further away from its reference potential (potential with no chlorides present) and can reach a value of -123 mV in a 60,000 ppm chloride solution.2 The chloride variations have been confirmed to some degree through laboratory testing.3 All of these factors must be considered when Cu/CuSO4 PRE durability tests are performed.
Long-term failure of PREs has been attributed to a dried-out PRE, which is a particular problem in dry soils. Consequently, PREs are often installed prepotted in a moisture-retaining backfill. The tendency for PREs to dry out is not addressed by this test method.
The natural tendency for the potential of a Cu/CuSO4 PRE to vary must also be considered. Some of this variation may ovvur as a result of the age of the PRE and/or differences in manufacturing. As a result, PREs are listed as being reputable to +/- mV4.
The tests described herein are relative tests that should only be used to compare PREs that are tested concurrently. Users should not attempt to draw meaningful conclusions from the results of tests performed at different times because the variations may be the result of uncontrolled differences between the two tests rather than the differences in the PREs themselves. The tests are intended to provide comparative data on Cu/CuDO4 PREs tested concurrently; therefore, no pass/fail criteria are established by this standard.
The tests described herein are relatively short in duration and there are insuffcient data to show a correlation between proper short-duration tests and expected service life. However, it would be reasonable to conclude that if one PRF lasts longer than another in these tests, similar relative durability could be expected in actual applications.
URI: http://yse.yabesh.ir/std;jsery=autho182693FD081DAC4261598F1EFDEC9FCD/handle/yse/217404
Collections :
  • NACE - NACE International
  • Download PDF : (192.7Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    NACE TM0211

Show full item record

contributor authorNACE - NACE International
date accessioned2017-09-04T18:35:22Z
date available2017-09-04T18:35:22Z
date copyright2011.06.24
date issued2011
identifier otherJIRBSEAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsery=autho182693FD081DAC4261598F1EFDEC9FCD/handle/yse/217404
description abstractThis standard describes a test method to measure specific physical properties and the relative stability of Cu/CuSO4 PREs when they are subjected to specific environmental stresses. These reference electrodes, while "permanent" in the physical sense (they are not commonly removed), do exhibit a finite service life. This test method is intended to provide a measure of the relative durability that may be expected. The test method specifically focuses on the ability of the Cu/CuSO4 PRE to (1) resist migration of CuSO4 from within the PRE into its surrounding environment and (2) to resist the migration of chloride from its surrounding environment into the PRE.
Unique field conditions may alter the durability of Cu/CuSO4 PREs. Factors such as temperature, sunlight, and soil contaminants can significantly affect PRE durability. Although consideration of these parameters is outside the scope of this standard, they may require consideration in certain field applications.
Environmental factors must be accounted for while performing durability testing. Articles have been written indicating possible factors resulting in erroneous potential measurements from a half-cell and their relevance to PREs.1.2 Variables that usually affect portable Cu/CuSO4 reference electrodes are temperature and sunlight variations. Both cited articles indicate that potential measurements can vary by 0.9 mV/degrees F), and that exposure to direct sunlight can cause variations in potential up to +20 mV. However, because PREs are typically used in locations with no direct sunlight exposure and limited temperature variations, such effects should be minimal1. Another environmental factor that can cause a change in potential is chloride contamination. This is generally only a problem with prolonged exposure to chloride- rich environments (e.g., seawater, brackish water, or chloride-rich soil). As the chloride contamination increases, the potential shifts further away from its reference potential (potential with no chlorides present) and can reach a value of -123 mV in a 60,000 ppm chloride solution.2 The chloride variations have been confirmed to some degree through laboratory testing.3 All of these factors must be considered when Cu/CuSO4 PRE durability tests are performed.
Long-term failure of PREs has been attributed to a dried-out PRE, which is a particular problem in dry soils. Consequently, PREs are often installed prepotted in a moisture-retaining backfill. The tendency for PREs to dry out is not addressed by this test method.
The natural tendency for the potential of a Cu/CuSO4 PRE to vary must also be considered. Some of this variation may ovvur as a result of the age of the PRE and/or differences in manufacturing. As a result, PREs are listed as being reputable to +/- mV4.
The tests described herein are relative tests that should only be used to compare PREs that are tested concurrently. Users should not attempt to draw meaningful conclusions from the results of tests performed at different times because the variations may be the result of uncontrolled differences between the two tests rather than the differences in the PREs themselves. The tests are intended to provide comparative data on Cu/CuDO4 PREs tested concurrently; therefore, no pass/fail criteria are established by this standard.
The tests described herein are relatively short in duration and there are insuffcient data to show a correlation between proper short-duration tests and expected service life. However, it would be reasonable to conclude that if one PRF lasts longer than another in these tests, similar relative durability could be expected in actual applications.
languageEnglish
titleNACE TM0211num
titleDurability Test for Copper/Copper Sulfate Permanent Reference Electrodes for Direct Burial Applications - Item No. 21257en
typestandard
page12
statusActive
treeNACE - NACE International:;2011
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian