NACE TM0177

English -- Laboratory Testing of Metals for Resistance to Sulfide Stress Cracking and Stress Corrosion Cracking in H2S Environments - Item No: 21212

Organization:
NACE - NACE International
Year: 2016

Abstract: Scope: Section 1: General This standard covers the testing of metals subjected to tensile stresses for resistance to cracking failure in low-pH aqueous environments containing H2S. Carbon and low-alloy steels are commonly tested for EC resistance at room temperature where SSC susceptibility is typically high. For other types of alloys, the correlation of EC susceptibility with temperature is more complicated. This standard describes reagents, test specimens, and equipment to use; discusses base material and test specimen properties; and specifies the test procedures to follow. This standard describes four test methods: Method A—Standard Tensile Test Method B—Standard Bent-Beam Test Method C—Standard C-Ring Test Method D—Standard Double-Cantilever-Beam (DCB) Test Sections 1 through 7 of this standard give general comments that apply to all four test methods. Sections 8 through 11 indicate the test method to follow for each type of test specimen. General guidelines to help to determine the suitability of each test method are given at the beginning of each test method description (Sections 8 through 11). Reporting of the test results is also discussed. Metals can be tested for resistance to EC at temperatures and pressures that are either ambient (atmospheric) or elevated. For testing at ambient conditions, the test procedures can be summarized as follows: Stressed test specimens are immersed in acidified aqueous environments containing H2S. Applied loads at convenient increments can be used to obtain EC data. For testing at temperatures higher than 27 °C (80 °F), at either atmospheric or elevated pressure, Section 7 describes an alternative test technique. All methods (A, B, C, and D) are adaptable to this technique. This standard may be used for release or acceptance testing to ensure that the product meets a certain minimum level of EC resistance as prescribed in API(2) Specification 5CT,3 ISO(3) 11960,4 or as prescribed by the user or purchaser. This standard may also provide a quantitative measure of the product’s EC resistance for research or informational purposes. This rating may be based on: Method A—The highest no-failure uniaxial tensile stress in 720 hours. Method B—The statistically based critical stress factor (Sc) for a 50% probability of failure in 720 hours. Method C—The highest no-failure circumferential stress in 720 hours. Method D—The average KISSC (threshold stress intensity factor for SSC) for valid tests of replicate test specimens. Safety Precautions: H2S is an extremely toxic gas that must be handled with care. (See Appendix A [Nonmandatory]). (2) American Petroleum Institute (API), 1220 L St. NW, Washington, DC 20005-4070. (3) International Organization for Standardization (ISO), Chemin de Blandonnet 8. Case Postale 401, 1214 Vermier, Geneva, Switzerland.
URI: http://yse.yabesh.ir/std;jsery=autho182693FD081DAC4261598F1EFDEC9FCD/handle/yse/233746
Collections :
  • NACE - NACE International
  • Download PDF : (1.141Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    NACE TM0177

Show full item record

contributor authorNACE - NACE International
date accessioned2017-10-18T11:01:03Z
date available2017-10-18T11:01:03Z
date copyright2016.04.18
date issued2016
identifier otherMUPTPFAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsery=autho182693FD081DAC4261598F1EFDEC9FCD/handle/yse/233746
description abstractScope: Section 1: General This standard covers the testing of metals subjected to tensile stresses for resistance to cracking failure in low-pH aqueous environments containing H2S. Carbon and low-alloy steels are commonly tested for EC resistance at room temperature where SSC susceptibility is typically high. For other types of alloys, the correlation of EC susceptibility with temperature is more complicated. This standard describes reagents, test specimens, and equipment to use; discusses base material and test specimen properties; and specifies the test procedures to follow. This standard describes four test methods: Method A—Standard Tensile Test Method B—Standard Bent-Beam Test Method C—Standard C-Ring Test Method D—Standard Double-Cantilever-Beam (DCB) Test Sections 1 through 7 of this standard give general comments that apply to all four test methods. Sections 8 through 11 indicate the test method to follow for each type of test specimen. General guidelines to help to determine the suitability of each test method are given at the beginning of each test method description (Sections 8 through 11). Reporting of the test results is also discussed. Metals can be tested for resistance to EC at temperatures and pressures that are either ambient (atmospheric) or elevated. For testing at ambient conditions, the test procedures can be summarized as follows: Stressed test specimens are immersed in acidified aqueous environments containing H2S. Applied loads at convenient increments can be used to obtain EC data. For testing at temperatures higher than 27 °C (80 °F), at either atmospheric or elevated pressure, Section 7 describes an alternative test technique. All methods (A, B, C, and D) are adaptable to this technique. This standard may be used for release or acceptance testing to ensure that the product meets a certain minimum level of EC resistance as prescribed in API(2) Specification 5CT,3 ISO(3) 11960,4 or as prescribed by the user or purchaser. This standard may also provide a quantitative measure of the product’s EC resistance for research or informational purposes. This rating may be based on: Method A—The highest no-failure uniaxial tensile stress in 720 hours. Method B—The statistically based critical stress factor (Sc) for a 50% probability of failure in 720 hours. Method C—The highest no-failure circumferential stress in 720 hours. Method D—The average KISSC (threshold stress intensity factor for SSC) for valid tests of replicate test specimens. Safety Precautions: H2S is an extremely toxic gas that must be handled with care. (See Appendix A [Nonmandatory]). (2) American Petroleum Institute (API), 1220 L St. NW, Washington, DC 20005-4070. (3) International Organization for Standardization (ISO), Chemin de Blandonnet 8. Case Postale 401, 1214 Vermier, Geneva, Switzerland.
languageEnglish
titleNACE TM0177num
titleEnglish -- Laboratory Testing of Metals for Resistance to Sulfide Stress Cracking and Stress Corrosion Cracking in H2S Environments - Item No: 21212en
typestandard
page77
statusActive
treeNACE - NACE International:;2016
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian