ASME PTC 12.1

Closed Feedwater Heaters

Organization:
ASME - ASME International
Year: 2015

Abstract: This Code applies to all horizontal and vertical heaters except those with partial pass full-length drain cooling zones. The heater design is based on a specific operating condition that includes flow, temperature, and pressure. This specific condition constitutes the design point that is found on the manufacturer’s feedwater heater specification sheet.
Generally, it is not possible to conduct the test at the exact design point. Therefore, it is necessary to predict the heater performance by adjusting the design parameters for the actual test conditions. Methods of calculating the predicted heater performance are presented in this Code. These predicted values shall then be compared to corresponding measured test values.
Horizontal heaters with partial pass submerged drain cooling zones and vertical channel-up heaters with partial pass drain cooling zones are not applicable to this Code. In those designs, only a portion of the feedwater passes through the drain cooling zones, therefore there are two flow streams with different temperature profiles.
Duplex heaters are applicable as long as the feedwater temperatures, including the temperature between stages, are measurable, and the shell sides are isolated from each other and verified to be at different stage pressures.
This Code is applicable for multitube pass heaters of single zone design. Multizone partial pass heaters cannot be tested under this Code, unless the entire first pass is contained in a single zone. This Code also does not apply to header type heaters.
URI: http://yse.yabesh.ir/std;jsery=autho470393FDFCDCAC4/handle/yse/215138
Collections :
  • ASME - ASME International
  • Download PDF : (1.145Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    ASME PTC 12.1

Show full item record

contributor authorASME - ASME International
date accessioned2017-09-04T18:32:55Z
date available2017-09-04T18:32:55Z
date copyright2015.01.01
date issued2015
identifier otherJCSFQFAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsery=autho470393FDFCDCAC4/handle/yse/215138
description abstractThis Code applies to all horizontal and vertical heaters except those with partial pass full-length drain cooling zones. The heater design is based on a specific operating condition that includes flow, temperature, and pressure. This specific condition constitutes the design point that is found on the manufacturer’s feedwater heater specification sheet.
Generally, it is not possible to conduct the test at the exact design point. Therefore, it is necessary to predict the heater performance by adjusting the design parameters for the actual test conditions. Methods of calculating the predicted heater performance are presented in this Code. These predicted values shall then be compared to corresponding measured test values.
Horizontal heaters with partial pass submerged drain cooling zones and vertical channel-up heaters with partial pass drain cooling zones are not applicable to this Code. In those designs, only a portion of the feedwater passes through the drain cooling zones, therefore there are two flow streams with different temperature profiles.
Duplex heaters are applicable as long as the feedwater temperatures, including the temperature between stages, are measurable, and the shell sides are isolated from each other and verified to be at different stage pressures.
This Code is applicable for multitube pass heaters of single zone design. Multizone partial pass heaters cannot be tested under this Code, unless the entire first pass is contained in a single zone. This Code also does not apply to header type heaters.
languageEnglish
titleASME PTC 12.1num
titleClosed Feedwater Heatersen
typestandard
page74
statusActive
treeASME - ASME International:;2015
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian