English -- UL Standard for Safety for Relocatable Structures - COMMENTS DUE: September 5, 2017

contributor authorUL - UL
date accessioned2017-10-18T11:12:27Z
date available2017-10-18T11:12:27Z
date copyright2017.06.02
date issued2017
identifier otherCWSIZFAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsery=authoF2376596081D20686159DD6E273C9FCD/handle/yse/236447
description abstractScope: This standard provides the requirements for modular built relocatable temporary structures. Relocatable structures for temporary use are a form of modular construction, built in an approved offsite facility, designed to be transported to a location, assembled, and utilized. During the life of these structures they may be used in several different locations. The buildings constructed under this standard are permitted to be of combustible construction or noncombustible construction, used singly or in combination, This standard specifies requirements including, but not limited to: a) National Building Code of Canada (NBC) objectives: i) safety; ii) health; and iii) fire & structural protection of buildings b) identification and labelling A building regulated by this standard need not meet the requirements of the Section 9.36 of the NBC, or the National Energy Code of Canada for Buildings (NECB) as it pertains to: a) the design and construction of the building envelope; and b) the design and construction or specification of systems and equipment for: i) lighting, heating, ventilating or air-conditioning; and ii) service water heating. See subsection 18.2 Insulation, 18.3 Ventilation, and Annex D, A18.2.1 This Standard applies to: a) a one storey building i) without sleeping accommodation, that is not more than 1 200 m2 in building area, and if sprinklered, is not more than 2 400 m2 in building area, and ii) with sleeping accommodation, that is not more than 600 m2 in building area, and if sprinklered, is not more than 1 200 m2 in building area, and b) a two storey building i) without sleeping accommodation, that is not more than 600 m2 in building area, and if sprinklered, is not more than 1 200 m2 in building area, and ii) with sleeping accommodation, that is not more than 300 m2 in building area, and if sprinklered, is not more than 600 m2 in building area. See 20.3 Building Cluster.  A building described in Clause 1.6 is permitted to consist of one or more transportable modules specifically designed to be readily relocatable and usable without permanent foundations.
languageEnglish
titleUL 2600 BULLETINnum
titleEnglish -- UL Standard for Safety for Relocatable Structures - COMMENTS DUE: September 5, 2017en
typestandard
page36
statusActive
treeUL - UL:;2017
contenttypefulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record