PROCEDURE FOR DETERMINING CONFORMANCE TO DRY COATING THICKNESS REQUIREMENTS

contributor authorSSPC - The Society for Protective Coatings
date accessioned2017-09-04T15:46:31Z
date available2017-09-04T15:46:31Z
date copyright05/01/2012
date issued2012
identifier otherPVLXXEAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsessionid=1532219FFCDC2D7C6159DD6E273C9FCD/handle/yse/49209
description abstractThis standard describes a procedure for determining shop or field conformance to a specified coating dry film thickness (DFT) range on ferrous and non-ferrous metal substrates using nondestructive coating thickness gages (magnetic and electronic) described in ASTM D 7091. 
The procedures for adjustment and measurement acquisition for two types of gages: "magnetic pull-off" (Type 1) and "electronic" (Type 2) are described in ASTM D 7091. 
This standard defines a procedure to determine whether dry coatings conform to the minimum and the maximum thickness specified. See Note 11.1 for an example of a possible modification when measuring dry film thickness on overcoated surfaces. 
This document is not intended to prescribe a frequency of coating thickness measurement for a coating failure investigation1
This document contains the following non-mandatory appendices:
Appendix 1 - Numerical Example of Average Thickness Measurement
Appendix 2 - Methods for Measuring Dry Film Thickness on Steel Beams (Girders)
Appendix 3 - Methods for Measuring Dry Film Thickness for a Laydown of Beams, Structural Steel, and Miscellaneous Parts after Shop Coating
Appendix 4 - Method for Measuring Dry Film Thickness on Coated Steel Test Panels
Appendix 5 - Method for Measuring Dry Film Thickness of Thin Coatings on Coated Steel Test Panels that Have Been Abrasive Blast Cleaned
Appendix 6 – Method for Measuring the Dry Film Thickness of Coatings on Edges
Appendix 7 – Method for Measuring Dry Film Thickness on Coated Steel Pipe Exterior
Appendix 8 – Examples of the Adjustment of Type 2 Gages Using Shims
This standard is not intended to be used for measurement of thermal spray coatings. The thickness measurement procedures for these coatings are described in SSPC-CS 23.002.
1 The number and location of measurements during a coating failure investigation may be more or less frequent than described by this standard.
2 CS 23.00/AWS C2.23M/NACE No. 12, Specification for the Application of Thermal Spray Coatings (Metallizing) of Aluminum, Zinc, and Their Alloys and Composites for the Corrosion Protection of Steel is available online at
languageEnglish
titleSSPC PA 2num
titlePROCEDURE FOR DETERMINING CONFORMANCE TO DRY COATING THICKNESS REQUIREMENTSen
typestandard
page11
statusActive
treeSSPC - The Society for Protective Coatings:;2012
contenttypefulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record