ASHRAE ST-16-013

English -- Experimental Setup and Methodology on Active Mechanisms for Enhancing Heat and Mass Transfer in Sorption Fluids

Organization:
ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
Year: 2016

Abstract: Scope: Enhancement of heat and mass transfer in sorption fluids could improve the overall performance of absorption chillers. Active mechanisms are proposed as a potential effective means to achieve this goal. A testing facility is needed to evaluate the impact on the performance of the chiller after adding an active mechanism. The challenges of this project include the fulfillment of mechanism motion to drive extra heat and mass transfer in an absorber, the measurement of related variables, and the stability and repeatability of findings. These challenges come from the fact that absorption chillers are closed-loop systems with large heat exchangers, have low inside pressures, andcansustain only small pressure drops alongthe refrigerant loop. Measures are needed to prevent the impact of vibration on untargeted components in the system. In this paper, we introduce the details of the lab construction methodology, including the vibration table, the auxiliary water loop system, and the measuring instruments. Then, we present several examples to show the operation and testing procedure and stability of the test system. Last, the experiment plan matrix and analysis methodology are presented, which will be applied in the next-phase experiment. The fulfillment of active mechanism and test methodology with a closed absorption chiller for performance analysis can be references in similar thermal applications.
URI: http://yse.yabesh.ir/std;jsessionid=435F2D89F77216F55ECC40BAF539160F/handle/yse/234671
Collections :
  • ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
  • Download PDF : (2.442Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    ASHRAE ST-16-013

Show full item record

contributor authorASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
date accessioned2017-10-18T11:04:51Z
date available2017-10-18T11:04:51Z
date copyright2016.01.01
date issued2016
identifier otherRIBQSFAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsessionid=435F2D89F77216F55ECC40BAF539160F/handle/yse/234671
description abstractScope: Enhancement of heat and mass transfer in sorption fluids could improve the overall performance of absorption chillers. Active mechanisms are proposed as a potential effective means to achieve this goal. A testing facility is needed to evaluate the impact on the performance of the chiller after adding an active mechanism. The challenges of this project include the fulfillment of mechanism motion to drive extra heat and mass transfer in an absorber, the measurement of related variables, and the stability and repeatability of findings. These challenges come from the fact that absorption chillers are closed-loop systems with large heat exchangers, have low inside pressures, andcansustain only small pressure drops alongthe refrigerant loop. Measures are needed to prevent the impact of vibration on untargeted components in the system. In this paper, we introduce the details of the lab construction methodology, including the vibration table, the auxiliary water loop system, and the measuring instruments. Then, we present several examples to show the operation and testing procedure and stability of the test system. Last, the experiment plan matrix and analysis methodology are presented, which will be applied in the next-phase experiment. The fulfillment of active mechanism and test methodology with a closed absorption chiller for performance analysis can be references in similar thermal applications.
languageEnglish
titleASHRAE ST-16-013num
titleEnglish -- Experimental Setup and Methodology on Active Mechanisms for Enhancing Heat and Mass Transfer in Sorption Fluidsen
typestandard
page12
statusActive
treeASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2016
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian