ASHRAE ST-16-016

English -- Simulated Energy-Efficient Voltage Frequency Ratios of Variable-Frequency Drives on Induction Motors

Organization:
ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
Year: 2016

Abstract: Scope: Variable-frequency drives (VFDs) are widely applied on induction motors that drive fans, pumps, and compressors. Under partial loads, VFDs not only adjust frequency to reduce motor speed and mechanical output power (load) but also adjust voltage to reduce motor electrical input power. Traditionally, VFD manufacturers recommend controlling the voltage so that it is proportional to the square of the frequency for variable torque motor loads on fans and pumps and proportional to the frequency for constant torque motor loads on compressors. The purpose of this paper is to investigate energy-efficient voltage frequency ratios of VFDs using the motor equivalent circuit method. First, the motor load and speed correlation are derived for different applications. Then, VFD voltage is optimized for a given VFD frequency to maximizemotorefficiency. Finally, themotorefficiency issimulated and compared under the optimal voltage and different preset voltages. The simulation results show that the motor efficiency with the ratio of voltage to frequency to the power of 1.5 is mostly close to the optimal efficiency for variable torque motor loads, and the motor efficiency with the ratio of voltage to frequency to the power of 0.5 is mostly close to the optimal efficiency for constanttorquemotorloadswithefficiencyimprovement by up to 3% over traditional ratios
URI: http://yse.yabesh.ir/std;jsessionid=435F2D89F77216F55ECC40BAF539160F/handle/yse/236616
Collections :
  • ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
  • Download PDF : (2.722Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    ASHRAE ST-16-016

Show full item record

contributor authorASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
date accessioned2017-10-18T11:13:02Z
date available2017-10-18T11:13:02Z
date copyright2016.01.01
date issued2016
identifier otherAJBQSFAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsessionid=435F2D89F77216F55ECC40BAF539160F/handle/yse/236616
description abstractScope: Variable-frequency drives (VFDs) are widely applied on induction motors that drive fans, pumps, and compressors. Under partial loads, VFDs not only adjust frequency to reduce motor speed and mechanical output power (load) but also adjust voltage to reduce motor electrical input power. Traditionally, VFD manufacturers recommend controlling the voltage so that it is proportional to the square of the frequency for variable torque motor loads on fans and pumps and proportional to the frequency for constant torque motor loads on compressors. The purpose of this paper is to investigate energy-efficient voltage frequency ratios of VFDs using the motor equivalent circuit method. First, the motor load and speed correlation are derived for different applications. Then, VFD voltage is optimized for a given VFD frequency to maximizemotorefficiency. Finally, themotorefficiency issimulated and compared under the optimal voltage and different preset voltages. The simulation results show that the motor efficiency with the ratio of voltage to frequency to the power of 1.5 is mostly close to the optimal efficiency for variable torque motor loads, and the motor efficiency with the ratio of voltage to frequency to the power of 0.5 is mostly close to the optimal efficiency for constanttorquemotorloadswithefficiencyimprovement by up to 3% over traditional ratios
languageEnglish
titleASHRAE ST-16-016num
titleEnglish -- Simulated Energy-Efficient Voltage Frequency Ratios of Variable-Frequency Drives on Induction Motorsen
typestandard
page11
statusActive
treeASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2016
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian