Standard Practice for Scanning Electron Microscope Beam Size Characterization

ASTM E986-04

Organization:
ASTM - ASTM International
Year: 2024

Abstract: 4.1 The traditional resolution test of the SEM requires, as a first step, a photomicrograph of a fine particulate sample taken at a high magnification. The operator is required to measure a distance on the photomicrograph between two adjacent, but separate edges. These edges are usually less than one millimetre apart. Their image quality is often less than optimum limited by the S/N ratio of a beam with such a small diameter and low current. Operator judgment is dependent on the individual acuity of the person making the measurement and can vary significantly. 4.2 Use of this practice results in SEM electron beam size characterization which is significantly more reproducible than the traditional resolution test using a fine particulate sample.
URI: http://yse.yabesh.ir/std;query=author:%22NAVY%20-%20YD%20-%20Naval%20Facilities%20Engineering%20Command%22/handle/yse/337829
Collections :
  • ASTM - ASTM International
  • Download PDF : (393.5Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    Standard Practice for Scanning Electron Microscope Beam Size Characterization

Show full item record

contributor authorASTM - ASTM International
date accessioned2024-12-17T23:28:45Z
date available2024-12-17T23:28:45Z
date copyright2024
date issued2024
identifier otherE0986-04r24.pdf
identifier urihttp://yse.yabesh.ir/std;query=author:%22NAVY%20-%20YD%20-%20Naval%20Facilities%20Engineering%20Command%22/handle/yse/337829
description abstract4.1 The traditional resolution test of the SEM requires, as a first step, a photomicrograph of a fine particulate sample taken at a high magnification. The operator is required to measure a distance on the photomicrograph between two adjacent, but separate edges. These edges are usually less than one millimetre apart. Their image quality is often less than optimum limited by the S/N ratio of a beam with such a small diameter and low current. Operator judgment is dependent on the individual acuity of the person making the measurement and can vary significantly. 4.2 Use of this practice results in SEM electron beam size characterization which is significantly more reproducible than the traditional resolution test using a fine particulate sample.
languageEnglish
titleStandard Practice for Scanning Electron Microscope Beam Size Characterizationen
titleASTM E986-04num
typestandard
page3
statusActive
treeASTM - ASTM International:;2024
contenttypefulltext
scope1.1 This practice provides a reproducible means by which one aspect of the performance of a scanning electron microscope (SEM) may be characterized. The resolution of an SEM depends on many factors, some of which are electron beam voltage and current, lens aberrations, contrast in the specimen, and operator-instrument-material interaction. However, the resolution for any set of conditions is limited by the size of the electron beam. This size can be quantified through the measurement of an effective apparent edge sharpness for a number of materials, two of which are suggested. This practice requires an SEM with the capability to perform line-scan traces, for example, Y-deflection waveform generation, for the suggested materials. The range of SEM magnification at which this practice is of utility is from 1000 × to 50 000 × . Higher magnifications may be attempted, but difficulty in making precise measurements can be expected. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
identifier DOI10.1520/E0986-04R24