• 0
    • ارسال درخواست
    • حذف همه
    • Industrial Standards
    • Defence Standards
  • درباره ما
  • درخواست موردی
  • فهرست استانداردها
    • Industrial Standards
    • Defence Standards
  • راهنما
  • Login
  • لیست خرید شما 0
    • ارسال درخواست
    • حذف همه
View Item 
  •   YSE
  • Industrial Standards
  • AASHTO - American Association of State Highway and Transportation Officials
  • View Item
  •   YSE
  • Industrial Standards
  • AASHTO - American Association of State Highway and Transportation Officials
  • View Item
  • All Fields
  • Title(or Doc Num)
  • Organization
  • Year
  • Subject
Advanced Search
JavaScript is disabled for your browser. Some features of this site may not work without it.

Archive

Guide Specifications for the Design of Concrete Bridge Beams Prestressed with Carbon Fiber-Reinforced Polymer (CFRP) Systems - First Edition

AASHTO CFRP

Organization:
AASHTO - American Association of State Highway and Transportation Officials
Year: 2018

Abstract: These guide specifications apply to the design of prestressed concrete beams constructed of normal weight concrete and prestressed by carbon fiberreinforced polymer (CFRP) prestressing systems. Unless otherwise specifically noted, these guide specifications are applicable to: • Concrete components made of concrete with compressive strengths used for design from 5.0 to 15.0 ksi, inclusive. • Pretensioned concrete beams. • Bonded and unbonded internally post-tensioned concrete beams. • Shear design of prestressed concrete bridge beams with only transverse steel reinforcement. Unless amended herein, the existing provisions of the AASHTO LRFD Bridge Design Specifications, Eighth Edition shall apply to the design of concrete beams prestressed with CFRP systems. References to articles in the AASHTO LRFD Bridge Design Specifications (AASHTO LRFD Design) are those of the eighth edition. References to articles in the AASHTO LRFD Bridge Construction Specifications are those of the fourth edition. The provisions of these guide specifications shall not be applied to: • Design of anchorage zones for external CFRP post-tensioned strengthening systems. • Design of partially prestressed concrete beams except that partial prestressing is allowed for posttensioned beams to resist the loads that are applied prior to application of the final post-tensioning. • Segmental construction and prestressed concrete bridge beams curved in plan. • Design for torsion.
URI: http://yse.yabesh.ir/std;jsessionid=51F9268D28B390B19128E8D5149CF289/handle/yse/280785
Collections :
  • AASHTO - American Association of State Highway and Transportation Officials
  • Download PDF : (4.604Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    Guide Specifications for the Design of Concrete Bridge Beams Prestressed with Carbon Fiber-Reinforced Polymer (CFRP) Systems - First Edition

Show full item record

contributor authorAASHTO - American Association of State Highway and Transportation Officials
date accessioned2020-08-07T18:32:16Z
date available2020-08-07T18:32:16Z
date issued2018
identifier otherDCWQGGAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsessionid=51F9268D28B390B19128E8D5149CF289/handle/yse/280785
description abstractThese guide specifications apply to the design of prestressed concrete beams constructed of normal weight concrete and prestressed by carbon fiberreinforced polymer (CFRP) prestressing systems. Unless otherwise specifically noted, these guide specifications are applicable to: • Concrete components made of concrete with compressive strengths used for design from 5.0 to 15.0 ksi, inclusive. • Pretensioned concrete beams. • Bonded and unbonded internally post-tensioned concrete beams. • Shear design of prestressed concrete bridge beams with only transverse steel reinforcement. Unless amended herein, the existing provisions of the AASHTO LRFD Bridge Design Specifications, Eighth Edition shall apply to the design of concrete beams prestressed with CFRP systems. References to articles in the AASHTO LRFD Bridge Design Specifications (AASHTO LRFD Design) are those of the eighth edition. References to articles in the AASHTO LRFD Bridge Construction Specifications are those of the fourth edition. The provisions of these guide specifications shall not be applied to: • Design of anchorage zones for external CFRP post-tensioned strengthening systems. • Design of partially prestressed concrete beams except that partial prestressing is allowed for posttensioned beams to resist the loads that are applied prior to application of the final post-tensioning. • Segmental construction and prestressed concrete bridge beams curved in plan. • Design for torsion.
languageEnglish
titleGuide Specifications for the Design of Concrete Bridge Beams Prestressed with Carbon Fiber-Reinforced Polymer (CFRP) Systems - First Editionen
titleAASHTO CFRPnum
typestandard
page71
statusActive
treeAASHTO - American Association of State Highway and Transportation Officials:;2018
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش