MANUALLY OPERATED ELECTRIC GAS IGNITION SYSTEMS AND COMPONENTS - First Edition

contributor authorCSA/AM - CSA America, Inc.
date accessioned2017-09-04T18:04:06Z
date available2017-09-04T18:04:06Z
date copyright2001.09.01 (R 2012)
date issued2012
identifier otherGFWCDFAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsessionid=94C855E48DF4B83399F154F279F912DC/handle/yse/186986
description abstractThis standard applies to newly produced manually-operated electric gas ignition systems (see Part IV, Definitions), hereinafter referred to as ignition systems, and ignition system components constructed entirely of new, unused parts and materials, which are intended to form an integral part of a gas appliance. An ignition system shall ignite gas at the main or pilot burner using either spark or hot surface ignition.
a. A spark ignition system shall:
1. Generate high voltage electric energy (spark generator);
2. Transmit the energy (high tension leads); and
3. Utilize the energy to produce arcs (spark electrode).
Components of spark ignition systems submitted for examination under this standard shall perform one or more of the above functions; however, a separate high tension lead(s) is not covered under the scope of this standard.
b. A hot surface ignition system shall:
1. Control energy to an igniter; and
2. Utilize the energy to heat an igniter.
A component of a hot surface ignition system submitted for examination under this standard shall perform one of the above functions.
This standard applies to ignition systems and components for use with one or more of the following gases:
a. Natural;
b. Manufactured;
c. Mixed;
d. Liquefied Petroleum; ande.
e. LP gas-air mixtures.
Compliance of an ignition system or component with this standard does not imply that either is acceptable for use on gas appliances without supplemental tests with the device(s) applied to the particular appliance design.
Each component of an ignition system shall be capable of operation throughout a temperature range of 32°F to 125°F (0°C to 52°C). The manufacturer is allowed to specify temperatures below 32°F (0°C) and above 125°F (52°C).
If a value for measurement as given in this standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification.
Exhibit C contains a list of standards referenced in this standard, and sources from which these reference standards may be obtained.
languageEnglish
titleCSA/AM ANSI Z21.92-2001/CSA 6.29-2001num
titleMANUALLY OPERATED ELECTRIC GAS IGNITION SYSTEMS AND COMPONENTS - First Editionen
typestandard
page50
statusActive
treeCSA/AM - CSA America, Inc.:;2012
contenttypefulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record