ISA 12.13.04

Performance Requirements for Open Path Combustible Gas Detectors

Organization:
ISA - International Society of Automation
Year: 2007

Abstract: This standard provides minimum requirements for fixed and transportable open path gas detection apparatus.
This standard specifies the construction, performance and testing of open path (line-of-sight) gas monitors that sense the presence of combustible gas or vapor concentrations in air.
For apparatus used for sensing the presence of multiple gases, this document applies only to the portion sensing the flammable gas or vapor. Sensing of toxic gases is outside the scope of this document.
This standard addresses combustible gas monitors intended to provide a broad indication or alarm, the purpose of which is to give warning of possible presence of a potential flammable concentration of gas or vapor.
Conformance to this standard does not imply suitability for gas monitoring or monitoring apparatus of the laboratory or scientific type used for analysis or measurement, apparatus used for process control and process monitoring purposes, or apparatus used for residential purposes.
This standard specifies the requirements for gas detection apparatus that are intended to monitor gases or vapors in ambient air by measuring the spectral absorption by the gases or vapors over an extended optical path. The units of measurement and range of the gas detection apparatus are a mathematical integral of the gas concentration along the optical path. The units of measurement are expressed as full concentration of the lower flammable limit (100%LFL or 1LFL) multiplied by the distance, in meters, at that concentration (e.g. LFL·meter, %LFL(Avg)).
This standard only specifies the requirements for instrument applications where calibration is performed using either the gas to be monitored or another gas for which response conversion data appears in the instruction manual
URI: http://yse.yabesh.ir/std;jsessionid=A33FFBB4A04818B251172099FA6814F7/handle/yse/128000
Collections :
  • ISA - International Society of Automation
  • Download PDF : (768.5Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    ISA 12.13.04

Show full item record

contributor authorISA - International Society of Automation
date accessioned2017-09-04T17:04:23Z
date available2017-09-04T17:04:23Z
date copyright03/07/2007
date issued2007
identifier otherXZPXYBAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsessionid=A33FFBB4A04818B251172099FA6814F7/handle/yse/128000
description abstractThis standard provides minimum requirements for fixed and transportable open path gas detection apparatus.
This standard specifies the construction, performance and testing of open path (line-of-sight) gas monitors that sense the presence of combustible gas or vapor concentrations in air.
For apparatus used for sensing the presence of multiple gases, this document applies only to the portion sensing the flammable gas or vapor. Sensing of toxic gases is outside the scope of this document.
This standard addresses combustible gas monitors intended to provide a broad indication or alarm, the purpose of which is to give warning of possible presence of a potential flammable concentration of gas or vapor.
Conformance to this standard does not imply suitability for gas monitoring or monitoring apparatus of the laboratory or scientific type used for analysis or measurement, apparatus used for process control and process monitoring purposes, or apparatus used for residential purposes.
This standard specifies the requirements for gas detection apparatus that are intended to monitor gases or vapors in ambient air by measuring the spectral absorption by the gases or vapors over an extended optical path. The units of measurement and range of the gas detection apparatus are a mathematical integral of the gas concentration along the optical path. The units of measurement are expressed as full concentration of the lower flammable limit (100%LFL or 1LFL) multiplied by the distance, in meters, at that concentration (e.g. LFL·meter, %LFL(Avg)).
This standard only specifies the requirements for instrument applications where calibration is performed using either the gas to be monitored or another gas for which response conversion data appears in the instruction manual
languageEnglish
titleISA 12.13.04num
titlePerformance Requirements for Open Path Combustible Gas Detectorsen
typestandard
page42
statusActive
treeISA - International Society of Automation:;2007
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian