Archive

English -- Standard Method of Test for Characterization of the Air-Void System of Freshly Mixed Concrete by the Sequential Pressure Method

AASHTO TP 118

Organization:
AASHTO - American Association of State Highway and Transportation Officials
Year: 2017

Abstract: Scope: This method covers determination of the air content and system air metric (SAM) number of freshly mixed concrete from observation of the change in volume of concrete with a sequential change in test pressure. This method is intended for use with concretes and mortars made with aggregates for which the aggregate correction factor can be satisfactorily determined by the technique described in Section 7. It is not applicable to concretes made with light-weight aggregates, air-cooled blastfurnace slag, or other aggregates with high porosity. This test method is also not applicable to nonplastic fresh concrete such as is commonly used in the manufacture of pipe and concrete masonry units. The text of this standard references notes and footnotes that provide explanatory information. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements for this standard. The values stated in inch-pound units are to be regarded as the standard. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure.
URI: http://yse.yabesh.ir/std;jsessionid=8194B13CB2DBC4D32CC206E52AF7469A/handle/yse/265868
Collections :
  • AASHTO - American Association of State Highway and Transportation Officials
  • Download PDF : (1.106Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    English -- Standard Method of Test for Characterization of the Air-Void System of Freshly Mixed Concrete by the Sequential Pressure Method

Show full item record

contributor authorAASHTO - American Association of State Highway and Transportation Officials
date accessioned2018-10-14T12:47:26Z
date available2018-10-14T12:47:26Z
date copyright2017.01.01 (R 2018)
date issued2017
identifier otherLXCAFGAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsessionid=8194B13CB2DBC4D32CC206E52AF7469A/handle/yse/265868
description abstractScope: This method covers determination of the air content and system air metric (SAM) number of freshly mixed concrete from observation of the change in volume of concrete with a sequential change in test pressure. This method is intended for use with concretes and mortars made with aggregates for which the aggregate correction factor can be satisfactorily determined by the technique described in Section 7. It is not applicable to concretes made with light-weight aggregates, air-cooled blastfurnace slag, or other aggregates with high porosity. This test method is also not applicable to nonplastic fresh concrete such as is commonly used in the manufacture of pipe and concrete masonry units. The text of this standard references notes and footnotes that provide explanatory information. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements for this standard. The values stated in inch-pound units are to be regarded as the standard. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure.
languageEnglish
titleEnglish -- Standard Method of Test for Characterization of the Air-Void System of Freshly Mixed Concrete by the Sequential Pressure Methoden
titleAASHTO TP 118num
typestandard
page12
statusActive
treeAASHTO - American Association of State Highway and Transportation Officials:;2017
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian