ISA TR92.06.03
Feasibility of Chlorine Detection Instrument Testing
| contributor author | ISA - International Society of Automation | |
| date accessioned | 2017-09-04T17:37:30Z | |
| date available | 2017-09-04T17:37:30Z | |
| date copyright | 07/07/2008 (R 2013) | |
| date issued | 2013 | |
| identifier other | DNFDCFAAAAAAAAAA.pdf | |
| identifier uri | http://yse.yabesh.ir/std;jsessioutho162s6596081D206/handle/yse/160365 | |
| description abstract | This report has been written to answer questions about the feasibility of performing the tests described in the ISA standard for chlorine gas detection instruments (ISA-92.06.01-1998). The report discusses two questions; the first is the availability of a chlorine gas supply of sufficient accuracy and precision for performing the tests, and the second is the viability of testing a gas detection instrument with chlorine under a variety of humidity conditions. The report surveys the available chemical literature, presents experimental and calculated results of humidity testing, and summarizes information on test gas generation and analysis. | |
| language | English | |
| title | ISA TR92.06.03 | num |
| title | Feasibility of Chlorine Detection Instrument Testing | en |
| type | standard | |
| page | 30 | |
| status | Active | |
| tree | ISA - International Society of Automation:;2013 | |
| contenttype | fulltext |