Show simple item record

English -- Manually operated ball valves and closed bottom taper plug valves for gas installations for buildings;
German -- Handbetaetigte Kugelhaehne und Kegelhaehne mit geschlossenem Boden fuer die Gas-Hausinstallation

contributor authorDIN - Deutsches Institut fš?r Normung e. V.
date accessioned2017-10-18T11:04:22Z
date available2017-10-18T11:04:22Z
date copyright2016.04.01
date issued2016
identifier otherQRSZOFAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsessioutho4703177793325273135A68A10958014A0Fa/handle/yse/234552
description abstractScope: This European Standard specifies the characteristics for the construction, performance and safety of ball valves and closed bottom taper plug valves. It also details the test methods and marking provisions. It applies to metallic valves not directly buried for domestic and commercial installations inside or outside of buildings, using gases of the first, second and third family (specified in EN 437) and working up to 0,2 × 105 Pa, 0,5 × 105 Pa, 1 × 105Pa, 5 × 105 Pa and 20 × 105Pa and with temperature limits from – 5 °C or −20 °C to + 60 °C. NOTE “Not directly buried” within the context of this standard means that valves below ground are not in direct contact with earth or other materials e.g. that they are in a protected encasement. Valve nominal sizes (DN) covered by this European Standard are as follows: 6, 8, 10, 12, 15, 20, 25, 32, 40, 50, 65, 80, 100.
languageEnglish
titleDIN EN 331num
titleEnglish -- Manually operated ball valves and closed bottom taper plug valves for gas installations for buildingsen
titleGerman -- Handbetaetigte Kugelhaehne und Kegelhaehne mit geschlossenem Boden fuer die Gas-Hausinstallationother
typestandard
page47
statusActive
treeDIN - Deutsches Institut fš?r Normung e. V.:;2016
contenttypefulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record