Show simple item record

|French -- Interface de programmation d'application pour système de gestion d'énergie (EMS-API) – Partie 456: Profils d'état de réseaux électriques résolus - Edition 2.0Energy management system application program interface (EMS-API) – Part 456: Solved po

contributor authorIEC - International Electrotechnical Commission
date accessioned2018-07-31T09:57:50Z
date available2018-07-31T09:57:50Z
date copyright2018.03.01
date issued2018
identifier otherCMAXEGAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsessiouthor:%22NAVY%20-%20YD%20-/handle/yse/264217
description abstractThis part of IEC 61970 belongs to the IEC 61970-450 to IEC 61970-499 series that, taken as a whole, define at an abstract level the content and exchange mechanisms used for data transmitted between power system analyses applications, control centers and/or control center components. The purpose of this document is to rigorously define the subset of classes, class attributes, and roles from the CIM necessary to describe the result of state estimation, power flow and other similar applications that produce a steady-state solution of a power network, under a set of use cases which are included informatively in this standard. This document is intended for two distinct audiences, data producers and data recipients, and may be read from those two perspectives. From the standpoint of model export software used by a data producer, the document describes how a producer may describe an instance of a network case in order to make it available to some other program. From the standpoint of a consumer, the document describes what that importing software must be able to interpret in order to consume power flow cases. There are many different use cases for which use of this document is expected and they differ in the way that the document will be applied in each case. Implementers are expected to consider what use cases they wish to cover in order to know the extent of different options they must cover. As an example, this document will be used in some cases to exchange starting conditions rather than solved conditions, so if this is an important use case, it means that a consumer application needs to be able to handle an unsolved state as well as one which has met some solution criteria.
languageEnglish
languageFrench
titleIEC 61970-456num
title|French -- Interface de programmation d'application pour système de gestion d'énergie (EMS-API) – Partie 456: Profils d'état de réseaux électriques résolus - Edition 2.0Energy management system application program interface (EMS-API) – Part 456: Solved poen
typestandard
page140
statusActive
treeIEC - International Electrotechnical Commission:;2018
contenttypefulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record