Show simple item record

|French -- Machines électriques tournantes – Partie 27-1: Mesurages à l’arrêt des décharges partielles effectués sur le système d'isolation des enroulements - Edition 1.0Rotating electrical machines – Part 27-1: Off-line partial discharge measurements on

contributor authorIEC - International Electrotechnical Commission
date accessioned2018-07-31T09:57:56Z
date available2018-07-31T09:57:56Z
date copyright2017.12.01
date issued2017
identifier otherEUKWCGAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;jsessiouthor:%22NAVY%20-%20YD%20-/handle/yse/264280
description abstractThis part of IEC 60034 provides a common basis for: – measuring techniques and instruments; – the arrangement of test circuits; – normalization and testing procedures; – noise reduction; – the documentation of test results; – the interpretation of test results, with respect to partial discharge off-line measurements on the winding insulation of rotating electrical machines. The measurement methods described in this document are applicable to stator windings of machines with or without conductive slot coating and to the stator windings of machines made with form wound or random wound windings. In special cases like high voltage rotor field windings, this document is applicable as well. The measurement methods are applicable when testing with alternating sinusoidal voltages from 0,1 Hz up to 400 Hz. Interpretation guidelines are given in this document and are applicable only if all the following requirements are fulfilled: – Measurements performed with power frequency of 50 Hz or 60 Hz, or when testing with power supply within a frequency range of 45 Hz to 65 Hz. – Form wound windings and winding components such as bars and coils. – Winding with conductive slot coating. This is usually valid for machines with voltage rating of 6 kV and higher. For machines with random wound windings, form-wound windings without conductive slot coating, and testing at frequencies differing from power frequencies, the interpretation guidelines are not applicable. The testing procedures for off-line PD-measurements of this document can be used for assessing the uniform quality of manufacturing or/and the trending of these kind of windings as well as converter driven machine windings. NOTE Testing of low voltage machines with so called Type I insulation systems is defined in reference [10]1. Testing procedures for qualification of converter driven high voltage machines with so called Type II insulation systems are dealt with in IEC 60034-18-42 (in addition to the optional electric tests described therein). 1 Numbers in square brackets refer to the Bibliography  
languageEnglish
languageFrench
titleIEC 60034-27-1num
title|French -- Machines électriques tournantes – Partie 27-1: Mesurages à l’arrêt des décharges partielles effectués sur le système d'isolation des enroulements - Edition 1.0Rotating electrical machines – Part 27-1: Off-line partial discharge measurements onen
typestandard
page138
statusActive
treeIEC - International Electrotechnical Commission:;2017
contenttypefulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record