ECA IS-749
Rectified Mains Application Expected Wear-Out Lifetime Test
| contributor author | ECIA - Electronic Components Industry Association | |
| date accessioned | 2017-09-04T18:43:02Z | |
| date available | 2017-09-04T18:43:02Z | |
| date copyright | 01/01/1998 | |
| date issued | 1998 | |
| identifier other | ALWMCAAAAAAAAAAA.pdf | |
| identifier uri | http://yse.yabesh.ir/std;quein=authoCA5893/handle/yse/224439 | |
| description abstract | This test procedure determines the expected wear-out lifetime for aluminum electrolytic capacitors. It provides a measure of the operating time required for parametric changes to cause capacitors to become unusable as filter capacitors on rectified mains applications. While it measures the time till wear-out, it does not indicate failure rate during the operating life. Wear-out is defined by conditions specified in table 1. Measurements are to be taken periodically and the measurements are to be taken at the same temperature throughout the test. | |
| language | English | |
| title | ECA IS-749 | num |
| title | Rectified Mains Application Expected Wear-Out Lifetime Test | en |
| type | standard | |
| page | 8 | |
| status | Active | |
| tree | ECIA - Electronic Components Industry Association:;1998 | |
| contenttype | fulltext |