Measurement and Warning of Radio Frequency Leakage from Microwave Tubes, Recommended Practice fo

contributor authorECIA - Electronic Components Industry Association
date accessioned2017-09-04T15:59:18Z
date available2017-09-04T15:59:18Z
date copyright01/01/1972 (R 1981)
date issued1981
identifier otherREYQCAAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;query=anid=47037D83081DAC4218546D6E273C9FCD/handle/yse/62408
description abstractThis test method applies to the measurement of unwanted radio frequency energy emitted from electron tubes designed to operate in the microwave region of 100 MHZ to 30 GHZ. It is assumed that the frequency, location and intensity of the leakage has been generally defined, using broadband equipment, and harmonics of the fundamental frequency and spurious (non-harmonic) leakage have bean examined and generally defined.
Purpose
To obtain the characteristic and level of radio frequency leakage from microwave tubes when these tubes are operated at operating parameters I as specified on the Tube Specification Sheet (TSS) without additional shielding.
languageEnglish
titleECA TEP 171num
titleMeasurement and Warning of Radio Frequency Leakage from Microwave Tubes, Recommended Practice foen
typestandard
page16
statusActive
treeECIA - Electronic Components Industry Association:;1981
contenttypefulltext