Medical electrical equipment — Part 2-16: Particular requirements for basic safety and essential performance of haemodialysis, haemodiafiltration and haemofiltration equipment - Third Edition

contributor authorCSA - CSA Group
date accessioned2017-09-04T18:47:35Z
date available2017-09-04T18:47:35Z
date copyright2009.11.01
date issued2009
identifier otherKMJKPCAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;query=autho1626AF679D40527361598F1ED52F014A/handle/yse/228770
description abstractAddition:
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of HAEMODIALYSIS, HAEMODIAFILTRATION and HAEMOFILTRATION EQUIPMENT, hereafter referred to as HAEMODIALYSIS EQUIPMENT.
This International standard does not take into consideration the DIALYSING FLUID control system of HAEMODIALYSIS EQUIPMENT using regeneration of DIALYSING FLUID and CENTRAL DELIVERY SYSTEMS. It does however take into consideration the specific safety requirements of such HAEMODIALYSIS EQUIPMENT concerning electrical safety and PATIENT safety.
This International standard specifies the minimum safety requirements for HAEMODIALYSIS EQUIPMENT. These devices are intended for use either by medical staff or for use by the PATIENT or other trained personnel under the supervision of medical expertise.
This International standard includes all ME EQUIPMENT that is intended to deliver a HAEMODIALYSIS, HAEMODIAFILTRATION and HAEMOFILTRATION treatment to a PATIENT suffering from kidney failure.
The particular requirements in this International standard do not apply to:
– EXTRACORPOREAL CIRCUITS;
– DIALYSERS;
– DIALYSING FLUID CONCENTRATES;
– water treatment equipment;
– equipment used to perform PERITONEAL DIALYSIS (see IEC 60601-2-39).
If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant.
HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this standard are not covered by specific requirements in this standard except in 7.2.13 and 8.4.1 of IEC 60601-1.
NOTE See also 4.2 of IEC 60601-1:2005.
languageEnglish
titleCSA CAN/CSA-C22.2 NO. 60601-2-16-09num
titleMedical electrical equipment — Part 2-16: Particular requirements for basic safety and essential performance of haemodialysis, haemodiafiltration and haemofiltration equipment - Third Editionen
typestandard
page70
statusActive
treeCSA - CSA Group:;2009
contenttypefulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record