Show simple item record

Crude Distillation Unit—Distillation Tower Overhead System Corrosion - Item No. 24240

contributor authorNACE - NACE International
date accessioned2017-09-04T15:11:26Z
date available2017-09-04T15:11:26Z
date copyright2009.12.01
date issued2009
identifier otherLUEQPCAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;query=autho162sAF679D4049A961598F1EFDEC014A0Facilities%114ngineering%20Command%22/handle/yse/9826
description abstractForeword
This state-of-the-art report describes the associated corrosion mechanisms in refinery crude distillation unit (CDU) distillation tower overhead systems and current industry practices for mitigating or controlling this corrosion. Distillation towers in a typical CDU may include a preflash tower, an atmospheric tower, and a vacuum tower. Feedstock, unit configurations, and associated process variables are addressed, from the crude oil storage tanks to the distillation tower overhead drums.
This report is intended as a technical resource for materials and corrosion specialists, process engineers, and operators at oil refining companies; chemical-treatment suppliers; and other companies involved in analyzing and preventing CDU distillation tower overhead corrosion.
This technical committee report was prepared by NACE International Task Group (TG) 342, "Crude Unit Distillation Tower Overhead Corrosion." TG 342 is administered by Specific Technology Group (STG) 34, "Petroleum Refining and Gas Processing." This technical committee report is issued by NACE International under the auspices of STG 34.
languageEnglish
titleNACE 34109num
titleCrude Distillation Unit—Distillation Tower Overhead System Corrosion - Item No. 24240en
typestandard
page85
statusActive
treeNACE - NACE International:;2009
contenttypefulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)