URINE PROCESSOR ASSEMBLY (UPA) MOTOR SPECIFICATION

contributor authorMSFC - NASA - MSFC - Marshall Space Flight Center
date accessioned2017-09-04T18:22:36Z
date available2017-09-04T18:22:36Z
date copyright08/16/2004
date issued2004
identifier otherIBXIJBAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;query=autho162sAF679D40AC421854DD6EFDEC9FCD/handle/yse/205045
description abstractThe scope of this document is limited to the performance specification for the four motors of the Urine Processor Assembly (UPA), which is an element of the Water Recovery System (WRS) for the International Space Station.
Purpose.
The purpose of this document is to establish the design, performance, safety, verification and interface requirements for the UPA's four motors, hereafter referred to as Motor 1 (M1), Motor 2 (M2), Motor 3 (M3), and actuator (M4).