Ultrasonic testing (UT) for tube thickness in black liquor recovery boilers: Part I - Guidelines for accurate tube thickness testing Part II - Default layouts for tube thickness surveys in various boiler zones

contributor authorTAPPI - TAPPI
date accessioned2017-09-04T17:51:38Z
date available2017-09-04T17:51:38Z
date copyright2010.01.01
date issued2010
identifier otherEZYEQCAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;query=autho162sear/handle/yse/174860
description abstractThis TIP is a review of general considerations related to UT thickness testing of black liquor recovery boiler tubes:
Part I of this TIP provides guidelines and procedures for acquiring accurate ultrasonic thickness readings on boiler tubes, where the tube material and condition are conducive to such non-destructive thickness testing.
Part II describes how tube thickness surveys are commonly laid out for different zones of a typical recovery boiler. It also stresses that a customized survey is essential for each boiler.
languageEnglish
titleTAPPI TIP 0402-18num
titleUltrasonic testing (UT) for tube thickness in black liquor recovery boilers: Part I - Guidelines for accurate tube thickness testing Part II - Default layouts for tube thickness surveys in various boiler zonesen
typestandard
page19
statusActive
treeTAPPI - TAPPI:;2010
contenttypefulltext
subject keywordsBlack liquor
subject keywordsCorrosion
subject keywordsInspection
subject keywordsNondestructive tests
subject keywordsRecovery boilers
subject keywordsThickness
subject keywordsTube
subject keywordsUltrasonic tests