Now showing items 561-580 of 2692

    • ASHRAE 26 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2010
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
      Abstract: This standard covers
      a. refrigerating and air-conditioning systems that are an integral part of the main mechanical plant of merchant, fishing, and seafood-processing ships and
      b. refrigerated seawater and ...
    • ASHRAE 52.2 ADD F 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2016
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
      Abstract: FOREWORD
      The technical committee received a change request stating “The data set and the resulting composite curve are the actual data product of the test method, whereas the MERV classification ...
    • ASHRAE APPLICATION SI CH 54 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2011
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • ASHRAE HVAC APPLICATIONS SI CH 9 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2015
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • ASHRAE LV-11-027 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2011
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
      Abstract: ABSTRACT
      This study investigates the optimization of the cooling tower condenser-water leaving temperature using a component- based model. This model consists of a chiller, a condenser-water pump, ...
    • ASHRAE OR-05-13-3 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2005
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • ASHRAE 185.1 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2015
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
      Abstract: This standard describes a method of laboratory testing to measure the performance of UV-C lights used in general ventilating systems.
      The method of test measures the performance of UV-C lights to inactivate selected ...
    • ASHRAE REFRIGERATION SI HANDBOOK 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2014
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • ASHRAE NY-08-048 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2008
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • ASHRAE REFRIGERATION SI CH 49 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2010
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • ASHRAE OR-16-C058 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2016
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
      Abstract: Heat pump water heaters (HPWHs) are one of the most energy efficient water heating options currently available in the Canadian market. These HPWHs operate by using electricity to circulate refrigerant in a loop to move ...
    • ASHRAE QC-06-017 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2006
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • ASHRAE APPLICATION IP CH 32 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2011
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • ASHRAE HVAC APPLICATIONS IP CH 49 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2015
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • ASHRAE AB-10-001 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2010
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
      Abstract: INTRODUCTION
      The straight flat oval duct pressure loss tests reported in and Idem et al. (2008) were performed with the same setups as depicted by Figures 2 and 3, where the larger ducts were tested ...
    • ASHRAE 4781 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2005
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • ASHRAE NY-08-020 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2008
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • ASHRAE REFRIGERATION SI CH 23 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2010
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • ASHRAE FUNDAMENTALS IP CH 39 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2009
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
      Abstract: THIS chapter describes the nature, functions, and performance of building envelopes. It concentrates on the interaction between the components of building envelopes and the subsequent effects on the interior environments ...
    • ASHRAE GUIDELINE 24 

      Type: standard
      Source: ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2015
      Organization : ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
      Abstract: This guideline primarily applies to ventilation and IAQ for human occupancy in residential buildings three stories or fewer in height above grade, including manufactured and modular houses.
      PURPOSE ...