Show simple item record

Hot-Water Distribution System Piping Time, Water, and Energy Waste—Phase III: Test Results

contributor authorASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
date accessioned2017-09-04T18:48:09Z
date available2017-09-04T18:48:09Z
date copyright01/01/2011
date issued2011
identifier otherKNXTKEAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;query=autho162sear79D/handle/yse/229364
description abstractABSTRACT
This paper describes results of recent laboratory tests on additional common hot-water distribution system piping sizes and types under a variety of flow rate, temperature, and environmental conditions. The new tests include chlorinated polyvinyl chloride (CPVC) and high-density cross-linked polyethylene (PEX) piping. They also include attic and floor environments. The tests measured the time spent waiting for hot water to arrive at fixtures and the amount of water wasted to drain while waiting. From these, the energy waste associated with the water waste can be computed. Results are presented as plots of the ratio of actual flow volume divided by pipe volume (AF/PV) vs. flow rate, temperatures, and other parameters of importance. Several unanticipated flow regimes were observed that dramatically alter behavior from what might be expected based on either plug-flow or fully developed flow theory. A separate related paper discusses piping heat loss UA factors that were measured.
languageEnglish
titleASHRAE LV-11-008num
titleHot-Water Distribution System Piping Time, Water, and Energy Waste—Phase III: Test Resultsen
typestandard
page13
statusActive
treeASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2011
contenttypefulltext