IEEE Recommended Practice for Partial Discharge Measurement in Liquid-Filled Power Transformers and Shunt Reactors

IEEE Std C57.113-2023 (Revision of IEEE Std C57.113-2010)

Organization:
IEEE - The Institute of Electrical and Electronics Engineers, Inc.
Year: 2024

IEEE - The Institute of Electrical and Electronics Engineers, Inc.

Abstract: Wideband measurement of the apparent charge of partial discharges (PDs) that may occur in liquid-filled power transformers and shunt reactors excited by ac test voltages between 40 Hz and 400 Hz are discussed. The major components of the PD measuring circuit including the calibrator are specified in compliance with IEC 60270. The PD test procedure is described and recommendations for the evaluation of PD test results are presented.
URI: http://yse.yabesh.ir/std;query=autho1826AF679D4049A961598F1EFDEC014A0Facilities%20Engineering%20Command%226EFDEC9FCD0Facilities%20Engineering%20Command%22/handle/yse/336449
Subject: apparent charge
Collections :
  • IEEE - The Institute of Electrical and Electronics Engineers, Inc.
  • Download PDF : (1.624Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    IEEE Recommended Practice for Partial Discharge Measurement in Liquid-Filled Power Transformers and Shunt Reactors

Show full item record

contributor authorIEEE - The Institute of Electrical and Electronics Engineers, Inc.
date accessioned2024-12-17T08:47:06Z
date available2024-12-17T08:47:06Z
date copyright12 March 2024
date issued2024
identifier other10471340.pdf
identifier urihttp://yse.yabesh.ir/std;query=autho1826AF679D4049A961598F1EFDEC014A0Facilities%20Engineering%20Command%226EFDEC9FCD0Facilities%20Engineering%20Command%22/handle/yse/336449
description abstractWideband measurement of the apparent charge of partial discharges (PDs) that may occur in liquid-filled power transformers and shunt reactors excited by ac test voltages between 40 Hz and 400 Hz are discussed. The major components of the PD measuring circuit including the calibrator are specified in compliance with IEC 60270. The PD test procedure is described and recommendations for the evaluation of PD test results are presented.
languageEnglish
publisherIEEE - The Institute of Electrical and Electronics Engineers, Inc.
titleIEEE Recommended Practice for Partial Discharge Measurement in Liquid-Filled Power Transformers and Shunt Reactorsen
titleIEEE Std C57.113-2023 (Revision of IEEE Std C57.113-2010)num
typestandard
page45
treeIEEE - The Institute of Electrical and Electronics Engineers, Inc.:;2024
contenttypefulltext
subject keywordsapparent charge
subject keywordspartial discharge
subject keywordsshunt reactor
subject keywordsPD
subject keywordswideband PD measurement
subject keywordsIEEE C57.113™
subject keywordspower transformer
identifier DOI10.1109/IEEESTD.2024.10471340