MIL-B-11188H

BATTERIES, STORAGE: LEAD-ACID, GENERAL SPECIFICATION FOR (METRIC)

Organization:
ARMY - AT - Tank-Automotive and Armaments Command
Year: 1994

Abstract: This specification covers waterproof, lead-acid storage batteries, furnished in charged and dry or charged and wet conditions, for starting, lighting and ignition service in military vehicles.
Storage batteries covered by this specifications shall be of the following types and conditions, as specified (see 3.5 and 6.2).
                                       Rated capacity                                        at 20-hour rate         Type          Voltage          Ampere - hours          2HN             12                  45          4HN             24                  21        Condition           A - Charged and dry           B - Charged and wet

Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: U.S. Army Tank-Automotive Command, ATTN: AMSTA-GLC, Warren, MI 48397-5000, by using the Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document, or by letter.
Intended Use: Batteries covered by this specification are intended primarily for starting, lighting, and ignition service in military vehicles, including tactical and administrative vehicles, internal combustion engine driven industrial trucks and tractors, construction equipment and generator sets. The batteries will also be used for radio operation and as a source of electrical energy for operating vehicular accessories, such as sighting devices and control mechanisms.
URI: http://yse.yabesh.ir/std/handle/yse/115404
Subject: Batteries
Collections :
  • ARMY - AT - Tank-Automotive and Armaments Command
  • Download PDF : (1.714Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    MIL-B-11188H

Show full item record

contributor authorARMY - AT - Tank-Automotive and Armaments Command
date accessioned2017-09-04T16:51:46Z
date available2017-09-04T16:51:46Z
date copyright09/13/1994
date issued1994
identifier otherWROYDAAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std/handle/yse/115404
description abstractThis specification covers waterproof, lead-acid storage batteries, furnished in charged and dry or charged and wet conditions, for starting, lighting and ignition service in military vehicles.
Storage batteries covered by this specifications shall be of the following types and conditions, as specified (see 3.5 and 6.2).
                                       Rated capacity                                        at 20-hour rate         Type          Voltage          Ampere - hours          2HN             12                  45          4HN             24                  21        Condition           A - Charged and dry           B - Charged and wet

Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: U.S. Army Tank-Automotive Command, ATTN: AMSTA-GLC, Warren, MI 48397-5000, by using the Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document, or by letter.
Intended Use: Batteries covered by this specification are intended primarily for starting, lighting, and ignition service in military vehicles, including tactical and administrative vehicles, internal combustion engine driven industrial trucks and tractors, construction equipment and generator sets. The batteries will also be used for radio operation and as a source of electrical energy for operating vehicular accessories, such as sighting devices and control mechanisms.
languageEnglish
titleMIL-B-11188Hnum
titleBATTERIES, STORAGE: LEAD-ACID, GENERAL SPECIFICATION FOR (METRIC)en
typestandard
page29
statusActive
treeARMY - AT - Tank-Automotive and Armaments Command:;1994
contenttypefulltext
subject keywordsBatteries
subject keywordsLead-Acid Batteries
subject keywordsStorage Batteries