Show simple item record

Analysis of Natural Gas Liquid Mixtures Containing Nitrogen and Carbon Dioxide by Gas Chromatography

contributor authorGPA - Gas Processors Association
date accessioned2017-09-04T16:07:52Z
date available2017-09-04T16:07:52Z
date copyright01/01/2003
date issued2003
identifier otherSCMJEBAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;query=autho1A5893FD081D20686159DD6E273C9FCD0Facilities%20Engineering%20Co/handle/yse/71067
description abstractThis method is intended for the analysis of demethanized liquid hydrocarbon streams containing nitrogen/air and carbon dioxide, and purity products such as an ethane/propane mix that fall within the compositional ranges listed in Table 1. This method is limited to mixtures containing less than 5 mol percent of heptanes and heavier fractions (20 mol percent of hexanes and heavier fractions).
The heptanes and heavier fraction if present in the sample is analyzed by either (1) use of a pre-cut column to elute heptanes and heavier first as a single peak or (2) reverse flow of carrier gas after n-hexane, and peak grouping of the heptanes plus fraction. For purity mixes without heptanes and heavier, no reverse of carrier flow is required.
Note 1 This method can be used for a hexanes plus analysis by adjusting the timing of the backflush event to occur following the elution of n-pentane.
Note 2 - CAUTION- In the case of unknown samples with a relatively large C6+ or C7+ fraction and where precise results are important, it is desirable to determine the molecular weight (or other pertinent physical properties) of these fractions. Since this method makes no provision for determining physical Properties, the physical properties needed must be determined by extended analysis or agreed to by the contracting parties. The extended analysis will be made according to GPA Publication 2186.
Note 3 - At this writing, GPA is developing a method for the analysis of samples containing more than 5 mol percent of heptanes and heavier fractions (20 mol percent of hexanes and heavier fractions).
languageEnglish
titleGPA STD 2177num
titleAnalysis of Natural Gas Liquid Mixtures Containing Nitrogen and Carbon Dioxide by Gas Chromatographyen
typestandard
page15
statusRevised
treeGPA - Gas Processors Association:;2003
contenttypefulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record