ECA 502-A
Recommended Practice for Measurement of X-Radiation from Non-Raster-Scanned Direct-View Cathode Ray Tubes
| contributor author | ECIA - Electronic Components Industry Association | |
| date accessioned | 2017-09-04T18:21:06Z | |
| date available | 2017-09-04T18:21:06Z | |
| date copyright | 03/01/1989 | |
| date issued | 1989 | |
| identifier other | HXXMCAAAAAAAAAAA.pdf | |
| identifier uri | http://yse.yabesh.ir/std;quessioutho4703177793325273135A68A10958014A0Fa/handle/yse/203569 | |
| description abstract | This test method applies to the measurement of x-radiation emitted from non-raster-scanned direct-view cathode ray tubes. For some applications the test procedures described in Recommended Standard EIA-501, "Recommended Practice for the Measurement of X-Radiation from Raster-Scanned Direct-View Data Display Cathode Ray Tubes," or EIA-503, "Recommended Practice for Measurement of X-Radiation from Direct-View Television Picture Tubes, It may be more appropriately used than those described herein. PURPOSE The purpose of this Standard is to obtain the x-radiation characteristics of non-raster-scanned direct-view data display cathode ray tubes in order to predict the levels emitted by tubes when electrical characteristics of the application are known. | |
| language | English | |
| title | ECA 502-A | num |
| title | Recommended Practice for Measurement of X-Radiation from Non-Raster-Scanned Direct-View Cathode Ray Tubes | en |
| type | standard | |
| page | 19 | |
| status | Active | |
| tree | ECIA - Electronic Components Industry Association:;1989 | |
| contenttype | fulltext |