Show simple item record

Implants for surgery — Wear of total intervertebral spinal disc prostheses — Part 2: Nucleus replacements - First Edition

contributor authorISO - International Organization for Standardization
date accessioned2017-09-04T18:43:20Z
date available2017-09-04T18:43:20Z
date copyright2010.06.15
date issued2010
identifier otherKBVGSCAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;query=autho47037D8369B/handle/yse/224783
description abstractThis part of ISO 18192 defines a test procedure for spinal nucleus prostheses under the relative angular movement conditions specified by ISO 18192-1.
This part of ISO 18192 is applicable to both lumbar and cervical prostheses. It is not applicable to total disc replacements and facet joint replacements. The method includes wear and fatigue testing. Additional mechanical tests such as creep tests can be required.
This part of ISO 18192 does not reproduce the complex in vivo loads and motions. The wear and fatigue data obtained with this test method will enable comparison between different types of implant but can differ from the clinical wear performance. The user of this part of ISO 18192 should consider running additional tests addressing specific safety issues of the individual implant design to be tested.
languageEnglish
titleISO 18192-2num
titleImplants for surgery — Wear of total intervertebral spinal disc prostheses — Part 2: Nucleus replacements - First Editionen
typestandard
page14
statusActive
treeISO - International Organization for Standardization:;2010
contenttypefulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record