Standard Method of Test for Moisture–Density Relations of Soil–Cement Mixtures
AASHTO T 134
Year: 2019
Abstract: These methods of test are intended for determining the relation between moisture content and density of soil–cement mixtures when compacted before cement hydration as prescribed.
A 944-cm3 (1/30-ft3) mold and a 2.5-kg (5.5-lb) rammer dropped from a height of 305 mm (12 in.) are used and two methods, depending on soil gradation, are covered, as follows:
Method A—Soil material passing a 4.75-mm (No. 4) sieve.
This method shall be used when 100 percent of the soil sample passes the 4.75-mm (No. 4) sieve; or
Method B—Soil material passing a 19.0-mm (3/4-in.) sieve.
This method shall be used when part of the soil sample is retained on the 4.75-mm (No. 4) sieve.
This test method applies to soil–cement mixtures that have 30 percent or less retained on the 19.0-mm (3/4-in.) sieve, when Method B is used.
The material retained on the 19.0 mm (3/4-in.) sieve shall be defined as oversized particles (coarse particles).
The following applies to all specified limits in this standard: For the purposes of determining conformance with these specifications, an observed value or a calculated value shall be rounded off “to the nearest unit” in the last right-hand place of figures used in expressing the limiting value, in accordance with ASTM E29
-
Statistics
Standard Method of Test for Moisture–Density Relations of Soil–Cement Mixtures
Show full item record
| contributor author | AASHTO - American Association of State Highway and Transportation Officials | |
| date accessioned | 2020-08-07T18:32:02Z | |
| date available | 2020-08-07T18:32:02Z | |
| date issued | 2019 | |
| identifier other | RMXOIGAAAAAAAAAA.pdf | |
| identifier uri | http://yse.yabesh.ir/std;query=autho1826AF679D/handle/yse/280740 | |
| description abstract | These methods of test are intended for determining the relation between moisture content and density of soil–cement mixtures when compacted before cement hydration as prescribed. A 944-cm3 (1/30-ft3) mold and a 2.5-kg (5.5-lb) rammer dropped from a height of 305 mm (12 in.) are used and two methods, depending on soil gradation, are covered, as follows: Method A—Soil material passing a 4.75-mm (No. 4) sieve. This method shall be used when 100 percent of the soil sample passes the 4.75-mm (No. 4) sieve; or Method B—Soil material passing a 19.0-mm (3/4-in.) sieve. This method shall be used when part of the soil sample is retained on the 4.75-mm (No. 4) sieve. This test method applies to soil–cement mixtures that have 30 percent or less retained on the 19.0-mm (3/4-in.) sieve, when Method B is used. The material retained on the 19.0 mm (3/4-in.) sieve shall be defined as oversized particles (coarse particles). The following applies to all specified limits in this standard: For the purposes of determining conformance with these specifications, an observed value or a calculated value shall be rounded off “to the nearest unit” in the last right-hand place of figures used in expressing the limiting value, in accordance with ASTM E29 | |
| language | English | |
| title | Standard Method of Test for Moisture–Density Relations of Soil–Cement Mixtures | en |
| title | AASHTO T 134 | num |
| type | standard | |
| page | 7 | |
| status | Active | |
| tree | AASHTO - American Association of State Highway and Transportation Officials:;2019 | |
| contenttype | fulltext |

درباره ما