Methods for Measuring the Change in Transmittance of Optical Fibers in Expressed Buffer Tubes When Subjected to Temperature Cycling

contributor authorTIA - Telecommunications Industry Association
date accessioned2017-09-04T18:24:15Z
date available2017-09-04T18:24:15Z
date copyright40823
date issued2011
identifier otherIGDFOEAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;query=autho47037D83FCDC49A961598F1EFDEC9FCD/handle/yse/206627
description abstractIntroduction
Intent
This test is applicable to cables containing a multiplicity of buffer tubes and specified for midspan access applications requiring expressed buffer tube storage (buffer tubes stored in their intact form; not cut, opened, or removed).
Storing several meters of expressed tubes in pedestals or splice cases is common field practice. This practice simplifies access to fibers for future reconfiguration or as a collateral result of accessing one or a few of the tubes in a cable.
The procedure in this document tests the ability of tubes to withstand temperature cycling without sustaining the specified induced fiber attenuation when the tubes are not constrained by other cable components or are only minimally constrained by slack management devices typically used in splice cases or pedestals.
Typical indications of failure are:
1. A temporary or permanent change in optical throughput which exceeds limits stated in the Detail Specification.
2. Cracks, blisters, or kinks of expressed buffer tubes.
languageEnglish
titleTIA TIA-455-244num
titleMethods for Measuring the Change in Transmittance of Optical Fibers in Expressed Buffer Tubes When Subjected to Temperature Cyclingen
typestandard
page18
statusActive
treeTIA - Telecommunications Industry Association:;2011
contenttypefulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record