Show simple item record

TP-43C Cable Clamping (Bending Moment) Test Procedure for Electrical Connectors

contributor authorECIA - Electronic Components Industry Association
date accessioned2017-09-04T16:55:08Z
date available2017-09-04T16:55:08Z
date copyright07/01/2013
date issued2013
identifier otherXAQXFFAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;query=autho470393FD081D20686159DD6EFDEC9FCD0Facilities%20Engineering%20Command%226EFDEC9FCD/handle/yse/118654
description abstractThis standard establishes a test method to determine the ability of connectors to withstand stress resulting from loads applied to rear accessory hardware such as might be experienced with cables hanging from plugs mated to wall-mounted receptacles. 
Typical damage Typical damage resulting from this test might be:
Cracked or broken shells. 
Loss of contact or shell continuity during or after load application. 
Reduction of shielding effectiveness.
Loss of seal integrity of receptacle at component interface.
Loss of seal integrity at plug/receptacle interface. 
Damaged receptacle mounting device.