TP-02D AIR LEAKAGE TEST PROCEDURE FOR ELECTRICAL CONNECTORS

contributor authorECIA - Electronic Components Industry Association
date accessioned2017-09-04T17:38:04Z
date available2017-09-04T17:38:04Z
date copyright04/01/2012
date issued2012
identifier otherDOSMWEAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;query=autho470393FD081D20686159DD6EFDEC9FCD0Facilities%20Engineering%20Command%226EFDEC9FCD/handle/yse/160956
description abstractThis standard establishes a method to determine the integrity of the seal of the shell, insert and contact interfaces in an electrical connector.
Object
The air leakage test may be conducted as one of the tests in a sequential test plan, and after or during the exposure of the test specimen to a specified temperature. Basically, this procedure consists of establishing a pressure differential between the front and rear faces of a mounted connector and measuring the degree of leakage through the seals of the test specimen by means of a detection device located on the low pressure side of the test specimen. Leakage may be determined by either the hermetic seal or environmental seal test methods as specified herein.
languageEnglish
titleECA EIA-364-02Dnum
titleTP-02D AIR LEAKAGE TEST PROCEDURE FOR ELECTRICAL CONNECTORSen
typestandard
page16
statusActive
treeECIA - Electronic Components Industry Association:;2012
contenttypefulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record