Calculation of Current Ratings on Hookup Wire, Method fo
contributor author | ECIA - Electronic Components Industry Association | |
date accessioned | 2017-09-04T17:40:01Z | |
date available | 2017-09-04T17:40:01Z | |
date copyright | 01/01/1958 (R 1981) | |
date issued | 1981 | |
identifier other | DUFZCAAAAAAAAAAA.pdf | |
identifier uri | http://yse.yabesh.ir/std;query=autho4/handle/yse/163041 | |
description abstract | The method of calculation provided by this recommended practice applies to the following conditions : Continuous currents and thermal equilibrium. Current may be either direct. or alternating. Alternating current may be single or multiphase, at frequencies up to 800 cycles per second: above 800 cycles, the AC resistance must be corrected for skin and proximity effects. Insulated wires in air subject to convection and radiation. Heat transfer from the wires to the surroundings by conduction is negligible. Specific environmental conditions such as altitude, ambient air temperature, type of convection, etc,, must be fixed for each calculation. Wire construction. Conductors of circular cross-section ; fabricated of any metal, solid or stranded. If stranded, the conductor should form a compact circular unit. Close-fitting insulation, concentric with the conductor, consisting of one or more layers of different materials. | |