Now showing items 1-20 of 42

      • NECA NEIS 600 

        Type: standard
        Source: NECA - National Electrical Contractors Association:;2003
        Organization : NECA - National Electrical Contractors Association
        Abstract: Products and Applications Included
        This recommended practice describes installation procedures for shielded and non-shielded soliddielectric medium-voltage cables rated from 600 Volts to 69,000 Volts ...
      • NECA NEIS 406 

        Type: standard
        Source: NECA - National Electrical Contractors Association:;2003
        Organization : NECA - National Electrical Contractors Association
        Abstract: Equipment Included
        This standard describes installation procedures for the following: a) Generator sets permanently installed at one-family dwellings to provide backup power. These are usually rated ...
      • NECA NEIS 111 

        Type: standard
        Source: NECA - National Electrical Contractors Association:;2003
        Organization : NECA - National Electrical Contractors Association
        Abstract: This standard describes installation procedures for nonmetallic raceways of circular cross-section used for electrical power wire and cable, communications wiring, or fiber optic cables.
        Products and Applications ...
      • NECA NEIS 102 

        Type: standard
        Source: NECA - National Electrical Contractors Association:;2004
        Organization : NECA - National Electrical Contractors Association
      • NECA NEIS 605 

        Type: standard
        Source: NECA - National Electrical Contractors Association:;2005
        Organization : NECA - National Electrical Contractors Association
        Abstract: This manual covers recommendations for shipping, handling, storage, installation, and joining of underground single bore nonmetallic duct for power, lighting, signaling, and communications applications.
        This manual is ...
      • NECA NEIS 503 

        Type: standard
        Source: NECA - National Electrical Contractors Association:;2005
        Organization : NECA - National Electrical Contractors Association
        Abstract: Products and Applications Included
        This standard describes installation procedures for glass fiber optics lighting systems.
        Products and Applications Excluded
        This standard ...
      • NECA NEIS 303 

        Type: standard
        Source: NECA - National Electrical Contractors Association:;2005
        Organization : NECA - National Electrical Contractors Association
        Abstract: This standard describes installation procedures for closed-circuit television system equipment installed for protection of building interiors, building perimeter, and surrounding property. This publication applies to ...
      • NECA NEIS 410 

        Type: standard
        Source: NECA - National Electrical Contractors Association:;2005
        Organization : NECA - National Electrical Contractors Association
        Abstract: Products and Applications Included
        This recommended practice describes installation procedures for pad-mounted, sealed, self-cooled, compartmental, single- and three-phase liquid-filled distribution ...
      • NECA NEIS 502 

        Type: standard
        Source: NECA - National Electrical Contractors Association:;2006
        Organization : NECA - National Electrical Contractors Association
        Abstract: Products and Equipment Included
        This standard describes installation procedures for lighting systems commonly used in industrial and storage buildings, including, but not limited to, the following: ...
      • NECA NEIS 568 

        Type: standard
        Source: NECA - National Electrical Contractors Association:;2006
        Organization : NECA - National Electrical Contractors Association
        Abstract: Products and Applications Included
        A structured cabling system is a complete collective configuration of cabling and associated hardware on a premises which, when installed, provides a comprehensive ...
      • NECA NEIS 430 

        Type: standard
        Source: NECA - National Electrical Contractors Association:;2006
        Organization : NECA - National Electrical Contractors Association
        Abstract: This standard describes site preparation and installation of medium-voltage metal-clad switchgear rated 5 kV and 15 kV AC.
        Products and Applications Included
        Metal-clad switchgear
        Vacuum circuit ...
      • NECA NEIS 100 

        Type: standard
        Source: NECA - National Electrical Contractors Association:;2006
        Organization : NECA - National Electrical Contractors Association
        Abstract: This publication describes graphic symbols used to represent electrical wiring and equipment on construction drawings. In this publication, the term "electrical" is used to include electrical, electronic, and communications ...
      • NECA NEIS 501 

        Type: standard
        Source: NECA - National Electrical Contractors Association:;2006
        Organization : NECA - National Electrical Contractors Association
        Abstract: Products and Applications Included
        This standard describes installation procedures for lighting systems commonly used in outdoor applications on and near commercial, institutional, industrial and storage ...
      • NECA NEIS 411 

        Type: standard
        Source: NECA - National Electrical Contractors Association:;2006
        Organization : NECA - National Electrical Contractors Association
        Abstract: This standard describes installation and maintenance procedures for permanently installed, static, threephase Uninterruptible Power Supplies (UPS) rated 30 kVA or more, and rated 600 Volts or less, and related battery ...
      • NECA NEIS 202 

        Type: standard
        Source: NECA - National Electrical Contractors Association:;2006
        Organization : NECA - National Electrical Contractors Association
        Abstract: Products and Applications Included
        This standard describes procedures for the installation, testing, and documentation of electrical freeze protection and process heat tracing systems. Heat tracing ...
      • NECA NEIS 120 

        Type: standard
        Source: NECA - National Electrical Contractors Association:;2006
        Organization : NECA - National Electrical Contractors Association
        Abstract: This standard covers the installation of Type AC and Type MC cables, which are used for electrical wiring for residential, commercial and industrial occupancies. It also includes information on fittings and other accessories ...
      • NECA NEIS 101 

        Type: standard
        Source: NECA - National Electrical Contractors Association:;2006
        Organization : NECA - National Electrical Contractors Association
        Abstract: This standard describes installation procedures for steel rigid metal conduit (RMC), steel intermediate metal conduit (IMC), and steel electrical metallic tubing (EMT). Conduit with supplementary PVC coating is also included. ...
      • NECA NEIS 500 

        Type: standard
        Source: NECA - National Electrical Contractors Association:;2006
        Organization : NECA - National Electrical Contractors Association
        Abstract: Products and Applications Included
        This standard describes installation procedures for lighting systems commonly used in commercial and retail buildings, including but not limited to the following: ...
      • NECA NEIS 105 

        Type: standard
        Source: NECA - National Electrical Contractors Association:;2007
        Organization : NECA - National Electrical Contractors Association
        Abstract: This publication addresses shipping, handling, storing, and installing cable tray systems. Information on maintenance and system modification is also provided.
      • NECA NEIS 400 

        Type: standard
        Source: NECA - National Electrical Contractors Association:;2007
        Organization : NECA - National Electrical Contractors Association
        Abstract: Products and Applications Included
        This standard desribes installation procedures for deadfront distribution switchboards rated 600 volts or less. This standard also covers periodic routine maintenance ...