Now showing items 621-640 of 832

    • A-A-52506C VALID NOTICE 1 

      Type: standard
      Source: ARMY - AT - Tank-Automotive and Armaments Command:;2011
      Organization : ARMY - AT - Tank-Automotive and Armaments Command
      Abstract: This CID covers metal hose clamps that are used for holding flexible ducts, or hose on to a male fitting. These hose clamps are generally used on coolant, fuel, oil, vacuum, and emission systems. The selection of type and ...
    • A-A-52597 

      Type: standard
      Source: ARMY - AT - Tank-Automotive and Armaments Command:;1996
      Organization : ARMY - AT - Tank-Automotive and Armaments Command
      Abstract: This CID covers requirements for cast-iron and steel swing check valves, hereinafter referred to as "valves", designed for liquid or gaseous petroleum products.
    • A-A-52543 

      Type: standard
      Source: ARMY - AT - Tank-Automotive and Armaments Command:;1995
      Organization : ARMY - AT - Tank-Automotive and Armaments Command
      Abstract: This CID covers requirements for a fifth wheel assembly used in coupling a truck-tractor to a trailer.
    • A-A-52532 

      Type: standard
      Source: ARMY - AT - Tank-Automotive and Armaments Command:;1995
      Organization : ARMY - AT - Tank-Automotive and Armaments Command
      Abstract: This CID covers the requirements for a universal socket used with the universal kingpin in coupling trailer to a truck-tractor or a trailer converter dolly fifth wheel.
    • A-A-52527B 

      Type: standard
      Source: ARMY - AT - Tank-Automotive and Armaments Command:;2008
      Organization : ARMY - AT - Tank-Automotive and Armaments Command
      Abstract: This CID covers a 6.0 meter platform-based freight container (herein called ‘collapsible flatrack') which is suitable for conveyance by road, rail, sea, and storage of military equipment.
    • A-A-59326/12B 

      Type: standard
      Source: ARMY - AT - Tank-Automotive and Armaments Command:;2011
      Organization : ARMY - AT - Tank-Automotive and Armaments Command
      Abstract: This specification covers a Male by Female type XI cam lock coupling reducer.
    • A-A-52524/6 

      Type: standard
      Source: ARMY - AT - Tank-Automotive and Armaments Command:;1995
      Organization : ARMY - AT - Tank-Automotive and Armaments Command
      Abstract: This CIDSS covers seals to be used as rotary shaft seals to retain oil and other fluids.
    • MIL-PRF-12126F VALID NOTICE 1 

      Type: standard
      Source: ARMY - AT - Tank-Automotive and Armaments Command:;2004
      Organization : ARMY - AT - Tank-Automotive and Armaments Command
    • A-A-52624A 

      Type: standard
      Source: ARMY - AT - Tank-Automotive and Armaments Command:;2001
      Organization : ARMY - AT - Tank-Automotive and Armaments Command
      Abstract: This commercial item description (CID) covers the requirements for ethylene glycol-based and propylene glycol-based automotive engine antifreeze. The antifreeze is to be suitable for use in all administrative vehicles, ...
      Subject(s) : Coolant , Engine , Ethylene , Freeze point , Glycol , Propylene ,
    • MIL-PRF-62365C VALID NOTICE 1 

      Type: standard
      Source: ARMY - AT - Tank-Automotive and Armaments Command:;2004
      Organization : ARMY - AT - Tank-Automotive and Armaments Command
    • A-A-59784 

      Type: standard
      Source: ARMY - AT - Tank-Automotive and Armaments Command:;2005
      Organization : ARMY - AT - Tank-Automotive and Armaments Command
      Abstract: This commercial item description (CID) covers E-Glass cloth used as the reinforcement media in the manufacture of advanced composite materials using infusion processes or hand lay-up.
      Subject(s) : E-glass , Fiber reinforced composites , Woven Roving ,
    • A-A-52446 

      Type: standard
      Source: ARMY - AT - Tank-Automotive and Armaments Command:;1994
      Organization : ARMY - AT - Tank-Automotive and Armaments Command
      Abstract: The General Services Administration has authorized the use of this commercial item description (CID) as a replacement for MIL-S-62502 (AT) which is canceled.
    • MIL-DTL-62736A 

      Type: standard
      Source: ARMY - AT - Tank-Automotive and Armaments Command:;1998
      Organization : ARMY - AT - Tank-Automotive and Armaments Command
      Abstract: This specification covers an Input/Output (I/O) Printed Wiring Assembly, herein referred to as the PWA. This is one of six printed wiring assemblies which comprise the Simplified Test Equipment/Internal Combustion ...
      Subject(s) : Automated Testing Equipment (ATE) test , Bus Transceiver , Crystal oscillator , Multiply/Divide Unit (MDU) , RS-232-C , RS-485 , Simplified Test Equipment/Internal Combustion Engine-Reprogrammable (STE/ICE-R) , Universal Asynchronous Receiver/Transmitter (UART) , Vehicle Test Meter (VTM) ,
    • A-A-59354 VALID NOTICE 1 

      Type: standard
      Source: ARMY - AT - Tank-Automotive and Armaments Command:;2005
      Organization : ARMY - AT - Tank-Automotive and Armaments Command
    • MIL-HDBK-21 

      Type: standard
      Source: ARMY - AT - Tank-Automotive and Armaments Command:;1995
      Organization : ARMY - AT - Tank-Automotive and Armaments Command
      Abstract: This handbook gives guidelines for particular welded joint designs used in the development of military armored tank type vehicles. This handbook is for guidance only. This handbook cannot be cited as a requirement. If ...
      Subject(s) : Armored , tank type , Continuous fillet , Double-bevel-grooved , corner joint , Intermittent-fillet-welded joint , Single-v-grooved , butt joint , Staggered intermittent-fillet , Welded joint designs ,
    • A-A-52524/6 VALID NOTICE 2 

      Type: standard
      Source: ARMY - AT - Tank-Automotive and Armaments Command:;2008
      Organization : ARMY - AT - Tank-Automotive and Armaments Command
    • A-A-52429A 

      Type: standard
      Source: ARMY - AT - Tank-Automotive and Armaments Command:;2009
      Organization : ARMY - AT - Tank-Automotive and Armaments Command
      Abstract: This CID establishes the requirements for a direct acting, poppet style, two-way shutoff solenoid operated valve for use on a military ground vehicle electronic drive system as an emergency bypass valve.
    • MIL-STD-162E 

      Type: standard
      Source: ARMY - AT - Tank-Automotive and Armaments Command:;1980
      Organization : ARMY - AT - Tank-Automotive and Armaments Command
      Abstract: This standard establishes the minimum requirements for level A, level B, level C, and Commercial preservation, packing and marking of self-propelled materials handling equipment for shipment from contractors or for storage ...
    • A-A-59326/20B 

      Type: standard
      Source: ARMY - AT - Tank-Automotive and Armaments Command:;2011
      Organization : ARMY - AT - Tank-Automotive and Armaments Command
      Abstract: This specification covers a Flanged Type XX wye (Y) Connection used in conjunction with flanged cam locking type couplings.
    • A-A-52539 VALID NOTICE 2 

      Type: standard
      Source: ARMY - AT - Tank-Automotive and Armaments Command:;2009
      Organization : ARMY - AT - Tank-Automotive and Armaments Command