TP-07C Contact Axial Concentricity Test Procedure for Electrical Connectors

contributor authorECIA - Electronic Components Industry Association
date accessioned2017-09-04T15:32:01Z
date available2017-09-04T15:32:01Z
date copyright07/01/2007 (R 2012)
date issued2012
identifier otherOFIJBFAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;query=authoCA5893FD081D527369727A00D52FAB6A/handle/yse/33571
description abstractThis standard establishes a test method to determine the straightness of contacts by measuring a total indicator reading (TIR) value. Axial concentricity can be measured after crimping to determine axial deformation.
languageEnglish
titleECA EIA/ECA-364-07Cnum
titleTP-07C Contact Axial Concentricity Test Procedure for Electrical Connectorsen
typestandard
page10
statusActive
treeECIA - Electronic Components Industry Association:;2012
contenttypefulltext