TP-78B CAVITY-TO-CAVITY LEAKAGE BONDING INTEGRITY TEST PROCEDURE FOR ELECTRICAL CONNECTORS

contributor authorECIA - Electronic Components Industry Association
date accessioned2017-09-04T15:38:13Z
date available2017-09-04T15:38:13Z
date copyright40483
date issued2010
identifier otherOXLUEDAAAAAAAAAA.pdf
identifier urihttp://yse.yabesh.ir/std;query=authoCA5893FD081D527369727A00D52FAB6A/handle/yse/40255
description abstractThis standard establishes a technique for evaluating the sealing integrity of the contact cavity walls of an environmentally sealed electrical connector by detecting leakage between a given contact cavity and those adjacent to it. This technique is suitable for application at the onset of a series of environmental tests (e.g., qualification or periodic inspection) to evaluate the soundness of the product before the start of test.