Standard Specification for Asphalt-Saturated Organic Felt Used in Roofing and Waterproofing
ASTM D226/D226M-25
Organization:
ASTM - ASTM International
Year: 2025
Abstract: This specification covers asphalt-saturated organic felt used in roofing and waterproofing. Two types of asphalt-saturated felts are presented: type I - commonly called No. 15 asphalt felt, and type II - commonly called No. 30 asphalt felt. In the process of manufacture a single thickness of dry felt shall be saturated with an asphaltic saturant. The methods for the determination of openness of the perforations in saturated felts are presented in detail.
Collections
:
-
Statistics
Standard Specification for Asphalt-Saturated Organic Felt Used in Roofing and Waterproofing
Show full item record
| contributor author | ASTM - ASTM International | |
| date accessioned | 2025-09-30T19:23:53Z | |
| date available | 2025-09-30T19:23:53Z | |
| date copyright | 2025 | |
| date issued | 2025 | |
| identifier other | d0226_d0226m-25.pdf | |
| identifier uri | http://yse.yabesh.ir/std;query=authoCA58ear3081D206861598F1EFDEC014A/handle/yse/343259 | |
| description abstract | This specification covers asphalt-saturated organic felt used in roofing and waterproofing. Two types of asphalt-saturated felts are presented: type I - commonly called No. 15 asphalt felt, and type II - commonly called No. 30 asphalt felt. In the process of manufacture a single thickness of dry felt shall be saturated with an asphaltic saturant. The methods for the determination of openness of the perforations in saturated felts are presented in detail. | |
| language | English | |
| title | Standard Specification for Asphalt-Saturated Organic Felt Used in Roofing and Waterproofing | en |
| title | ASTM D226/D226M-25 | num |
| type | standard | |
| status | Active | |
| tree | ASTM - ASTM International:;2025 | |
| contenttype | fulltext | |
| scope | 1.1 This specification covers asphalt-saturated organic felts intended to be used in the following applications: 1.1.1 As underlayment for steep slope roofing products in the construction of steep slope roofing systems; 1.1.2 As ply in low-slope built-up roof applications. The felts, with or without perforations, are intended to be used with asphalts conforming to the requirements of Specification D312/D312M; 1.1.3 As waterproofing barrier with asphalts conforming to the requirements of Specification D449/D449M in the construction of water proofing systems. 1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.3 The following safety hazards caveat pertains only to the test method portion, Section 8, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. | |
| identifier DOI | 10.1520/D0226_D0226M-25 |

درباره ما