Standard Test Method for Cell Size of Rigid Cellular Plastics

ASTM D3576-25

Organization:
ASTM - ASTM International
Year: 2025

Abstract: 5.1 Several physical properties of rigid cellular plastics are dependent on cell size and cell orientation. Measuring water absorption and open-cell content in accordance with Test Method D2842 Procedure A, and Test Method D6226 requires knowledge of surface cell volume, which uses cell size values in the calculations. 5.2 This test method provides an apparent cell size because it assumes that there is no measurable edge to edge or top to bottom variation in average cell size and that the cell size distribution about the average cell size is normal. If the analyst is concerned there may be significant variation in either the average cell size or the cell size distribution more detailed analysis may be required. 5.3 Before proceeding with this test method, reference should be made to the specification of the material being tested. Any test specimen preparation, conditioning, dimensions, or testing parameters, or a combination thereof, covered in the materials specification shall take precedence over those mentioned in this test method. If there are no material specifications, then the default conditions apply.
URI: http://yse.yabesh.ir/std;jsery=autho1826ear3081DAC4/handle/yse/343427
Collections :
  • ASTM - ASTM International
  • Download PDF : (478.0Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    Standard Test Method for Cell Size of Rigid Cellular Plastics

Show full item record

contributor authorASTM - ASTM International
date accessioned2025-09-30T19:25:18Z
date available2025-09-30T19:25:18Z
date copyright2025
date issued2025
identifier otherd3576-25.pdf
identifier urihttp://yse.yabesh.ir/std;jsery=autho1826ear3081DAC4/handle/yse/343427
description abstract5.1 Several physical properties of rigid cellular plastics are dependent on cell size and cell orientation. Measuring water absorption and open-cell content in accordance with Test Method D2842 Procedure A, and Test Method D6226 requires knowledge of surface cell volume, which uses cell size values in the calculations. 5.2 This test method provides an apparent cell size because it assumes that there is no measurable edge to edge or top to bottom variation in average cell size and that the cell size distribution about the average cell size is normal. If the analyst is concerned there may be significant variation in either the average cell size or the cell size distribution more detailed analysis may be required. 5.3 Before proceeding with this test method, reference should be made to the specification of the material being tested. Any test specimen preparation, conditioning, dimensions, or testing parameters, or a combination thereof, covered in the materials specification shall take precedence over those mentioned in this test method. If there are no material specifications, then the default conditions apply.
languageEnglish
titleStandard Test Method for Cell Size of Rigid Cellular Plasticsen
titleASTM D3576-25num
typestandard
statusActive
treeASTM - ASTM International:;2025
contenttypefulltext
scope1.1 This test method covers the determination of the apparent cell size of rigid cellular plastics by counting the number of cell-wall intersections in a specified distance. 1.2 Procedure A requires the preparation of a thin slice, not more than one half the average cell diameter in thickness, that is mechanically stable. For most rigid cellular plastics this limits the test method to materials with an average cell size of at least 0.2 mm. 1.3 Procedure B is intended for use with materials whose friable nature makes it difficult to obtain a thin slice for viewing. 1.4 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Note 1: The annex to ISO 2896 is technically equivalent to this test method. 1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
identifier DOI10.1520/D3576-25
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian