description abstractThis International Standard gives specifications applicable to all transformers for resistance welding equipment with or without connected rectifier.
The following types are included:
- single-phase transformers for alternating welding current, typically operating at 50 Hz or 60 Hz;
- single-phase transformers with connected rectifier typically operating at 50 Hz or 60 Hz;
- single-phase inverter welding transformer with connected rectifier typically operating at 400 Hz to 2 kHz;
- three-phase transformers with connected rectifier typically operating at 50 Hz or 60 Hz.
NOTE 1 Typical operating frequencies are given for information only and are not exclusive.
For the purposes of this International Standard, a transformer can refer to the transformer alone or combined with other components such as a rectifier, as listed above.
This International Standard applies to transformers built to protection class I or II according to IEC 61140.
NOTE 2 This International Standard provides fundamental requirements that can be supplemented by other resistance welding transformer standards e.g. ISO 22829 and ISO 10656.
languageEnglish
titleISO DIS 5826.2num
titleResistance welding equipment - Transformers - General specifications applicable to all transformersen
typestandard
page35
statusDraft
treeISO - International Organization for Standardization:;2013
contenttypefulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record